首页> 外文期刊>Dental Materials Journal >Influence of the difference between implant body and screw materials on abutment screw loosening
【24h】

Influence of the difference between implant body and screw materials on abutment screw loosening

机译:种植体和螺钉材料之间的差异对基台螺钉松动的影响

获取原文
           

摘要

The purpose of this study was to investigate how differences in dental implant and screw materials affected screw loosening. Screws (pure titanium; Ti4S, titanium alloy; TiAS), blocks (Y-TZP; ZrB, pure titanium; Ti4B) and plates (Y-TZP; ZrP), representing abutment screws, implant bodies and superstructures, respectably, were used. Plates were fastened to blocks by screws using a torque of 20 N?cm, and the loosening torque was measured after cyclic loading. Tests was performed on 13 specimens per group, with four groups for loading at the eccentric point (9 mm from screw center) and one group at the centric point (3 mm from screw center). In eccentric point tests, Ti4S screws led to significantly more loosening than TiAS screws (p <0.01). The block material had no effect. For ZrBTi4S, there was no difference in loosening before and after the centric point tests. More loosening occurred for eccentric point than for centric point tests (p <0.05).
机译:这项研究的目的是调查牙种植体和螺钉材料的差异如何影响螺钉的松动。分别使用螺钉(纯钛; Ti4S,钛合金; TiAS),块(Y-TZP; ZrB,纯钛; Ti4B)和板(Y-TZP; ZrP),分别代表了基台螺钉,植入体和上部结构。用20N·cm 2的扭矩通过螺钉将板紧固至块,并在循环加载后测量松动扭矩。每组对13个样品进行测试,其中四组分别在偏心点(距螺钉中心9 mm)处加载,一组在中心点(距螺钉中心3 mm)处加载。在偏心点测试中,与TiAS螺钉相比,Ti4S螺钉导致的松动明显更多(p <0.01)。块料没有作用。对于ZrBTi4S,在中心点测试之前和之后的松动没有差异。与中心点测试相比,偏心点发生的松动更大(> 0.05)。