首页> 外文期刊>Health and Quality of Life Outcomes >A brief patient-reported outcome instrument for primary care: German translation and validation of the Measure Yourself Medical Outcome Profile (MYMOP)
【24h】

A brief patient-reported outcome instrument for primary care: German translation and validation of the Measure Yourself Medical Outcome Profile (MYMOP)

机译:简短的患者报告的初级保健结局工具:德语翻译和“测量您自己的医疗结果概况”(MYMOP)的验证

获取原文
           

摘要

Background Measure Yourself Medical Outcome Profile (MYMOP) is a patient-generated outcome instrument capable of measuring effects from a wide range of health care interventions. This paper reports the translation of this instrument into German (MYMOP-D) and the assessment of validity and sensitivity to change for the MYMOP-D. The instrument was piloted in a German primary care context. Methods The translation process was conducted according to international guidelines. Recruited patients of both general practitioners and non-medical Complementary and Alternative Medicine (CAM) practitioners (“Heilpraktiker”) in the German state of Baden-Wuerttemberg completed a questionnaire comprised of the MYMOP-D and the EQ-5D. Responses were analysed to assess construct validity. For assessing the instrument’s sensitivity to change, patients received the MYMOP-D again after four weeks at which point they were also asked for their subjective views on change of symptoms. Correlation between MYMOP-D and EQ-5D and sensitivity to change as gradient in score change and as standardized response mean (SRM) were calculated. Results 476 patients from general practices and 91 patients of CAM practitioners were included. Construct validity of the MYMOP-D was given with a correlation of r?=?.47 with the EQ-5D. Sensitivity to change for subjective change of symptoms could only be analysed for improvement or no change of symptoms, as only 12 patients reported deterioration of symptoms. Results showed the expected smooth gradient with 2.2, 1.3, and 0.5 points of change for large, little improvement and no change, respectively. SRM for MYMOP-D Profile Score was 0.88. Conclusions The MYMOP-D shows excellent construct validity. It is able to detect changes when symptoms in patients improve or remain unchanged. Deterioration of symptoms could not be evaluated due to too few data. With its brevity and simplicity, it might be an important tool for enhancing patient-centred care in the German health care context.
机译:背景自行测量医疗成果概况(MYMOP)是一种由患者生成的成果工具,能够衡量各种卫生保健干预措施的效果。本文报告了该仪器翻译成德文(MYMOP-D)以及评估MYMOP-D有效性和变更敏感性的方法。该仪器是在德国的初级保健环境中试用的。方法按照国际准则进行翻译。来自德国巴登-符腾堡州的全科医师和非医学补充与替代医学(CAM)医师(“ Heilpraktiker”)的已招募患者填写了一份由MYMOP-D和EQ-5D组成的问卷。分析响应以评估构建体的有效性。为了评估仪器对变化的敏感性,患者在四周后再次接受MYMOP-D治疗,此时他们还被要求征求他们对症状变化的主观意见。计算了MYMOP-D和EQ-5D之间的相关性以及随着分数变化的梯度和标准化响应平均值(SRM)而变化的敏感性。结果纳入了476例一般实践患者和91例CAM从业者。 MYMOP-D的构建效度与EQ-5D的相关性为r?= ?. 47。由于只有12例患者报告症状恶化,因此只能分析症状的主观变化对变化的敏感性。结果表明,预期的平滑梯度分别有2.2、1.3和0.5个变化点,变化较大,几乎没有改善,并且没有变化。 MYMOP-D档案得分的SRM为0.88。结论MYMOP-D具有良好的构建效度。当患者症状改善或保持不变时,它能够检测到变化。由于数据太少,无法评估症状恶化。凭借其简洁性和简便性,它可能是在德国医疗保健领域中增强以患者为中心的护理的重要工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号