首页> 外文期刊>Yonsei Medical Journal >Usefulness of Chest Radiographs for Scoliosis Screening: A Comparison with Thoraco-Lumbar Standing Radiographs
【24h】

Usefulness of Chest Radiographs for Scoliosis Screening: A Comparison with Thoraco-Lumbar Standing Radiographs

机译:胸部X光片对脊柱侧弯检查的实用性:与胸腰椎X光片的比较

获取原文
           

摘要

Purpose The purposes of this study were to evaluate the usefulness and limitations of chest radiographs in scoliosis screening and to compare these results with those of thoraco-lumbar standing radiographs (TLSR). Materials and Methods During Korean conscription, 419 males were retrospectively examined using both chest radiographs and TLSR to confirm the scoliosis and Cobb angle at the Regional Military Manpower. We compared the types of spinal curves and Cobb angles as measured from different radiographs. Results In the pattern of spinal curves, the overall matching rate of chest radiographs using TLSR was about 58.2% (244 of 419 cases). Cobb angle differences between chest radiographs and TLSR with meaningful difference was observed in 156 cases (37.2%); a relatively high proportion (9.5%) of Cobb angle differences more than 10 degrees was also observed. The matching rate of both spinal curve types and Cobb angle accuracy between chest radiographs and TLSR was 27.9% (117 among 419 cases). Chest radiographs for scoliosis screening were observed with 93.94% of sensitivity and 61.67% of specificity in thoracic curves; however, less than 40% of sensitivity (38.27%, 20.00%, and 25.80%) and more than 95% of specificity (97.34%, 99.69%, and 98.45%) were observed in thoraco-lumbar, lumbar, and double major curves, respectively. Conclusion The accuracy of chest radiographs for scoliosis screening was low. The incidence of thoracic curve scoliosis was overestimated and lumbar curve scoliosis was easily missed by chest radiography. Scoliosis screening using chest radiography has limited values, nevertheless, it is useful method for detecting thoracic curve scoliosis.
机译:目的这项研究的目的是评估胸部X光片在脊柱侧凸筛查中的有用性和局限性,并将这些结果与胸腰段X光片(TLSR)进行比较。材料和方法在韩国征兵期间,使用胸部X光片和TLSR回顾性检查了419名男性,以确认区域军事人员的脊柱侧弯和Cobb角。我们比较了从不同的X射线照片测得的脊柱曲线和Cobb角的类型。结果在脊柱弯曲模式中,使用TLSR的胸部X光片的总匹配率约为58.2%(419例中的244例)。胸片和TLSR之间的Cobb角差异为156例(37.2%),具有有意义的差异。还观察到相对较高比例(9.5%)的Cobb角差异超过10度。 X线胸片与TLSR的脊柱曲线类型和Cobb角准确性的匹配率为27.9%(419例中为117例)。胸部影像学检查可对脊柱侧弯进行检查,胸廓曲线的敏感性为93.94%,特异性为61.67%。然而,在胸腰椎,腰部和双主曲线中,观察不到敏感性的40%(38.27%,20.00%和25.80%)和特异性的95%以上(97.34%,99.69%和98.45%)。 , 分别。结论胸部X线片检查脊柱侧弯的准确性较低。胸部X线照片容易高估了胸弯脊柱侧弯的发生率,而腰弯脊柱侧弯很容易被漏诊。使用胸部放射线照相术进行脊柱侧弯筛查的价值有限,但是,它是检测胸曲线脊柱侧弯的有用方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号