...
首页> 外文期刊>Yonsei Medical Journal >Evaluation of Postoperative Range of Motion and Functional Outcomes after Cruciate-Retaining and Posterior-Stabilized High-Flexion Total Knee Arthroplasty
【24h】

Evaluation of Postoperative Range of Motion and Functional Outcomes after Cruciate-Retaining and Posterior-Stabilized High-Flexion Total Knee Arthroplasty

机译:保留交叉和后稳定的高屈曲全膝关节置换术后的运动范围和功能结果的评估

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Purpose The purpose of this study was to compare postoperative range of motion and functional outcomes among patients who received high-flexion total knee arthroplasty using cruciate-retaining (CR-Flex) and posterior-stabilized (PS-Flex) type prostheses. Materials and Methods Among 127 patients (186 knees) who underwent high-flexion total knee arthroplasty between 2005 and 2007, 92 knees were placed in the CR-Flex group, and 94 knees were placed in the PS-Flex group. After two years of postoperative follow-up, clinical and radiographic data were reviewed. Postoperative non-weight-bearing range of knee motion, angle of flexion contracture and functional outcomes based on the Western Ontario and McMaster Universities Osteoarthritis (WOMAC) functional sub-scale were assessed and compared between the two groups. Results After the 2-year postoperative period, the mean range of motion was 131° in the CR-Flex group and 133° in the PS-Flex group. There were no significant differences in postoperative range of motion between the two groups. Only age at operation and preoperative range of motion were significantly associated with postoperative range of motion after high-flexion total knee arthroplasty. Postoperative functional outcomes based on the WOMAC functional sub-scale were slightly better in the CR-Flex group (9.2±9.1 points) than in the PS-Flex group (11.9±9.6 points); however, this difference was not statistically significant ( p =non-significant). Conclusion The retention or substitution of the posterior cruciate ligament does not affect postoperative range of motion (ROM) or functional outcomes, according to 2 years of postoperative follow-up of high-flexion total knee arthroplasty.
机译:目的这项研究的目的是比较使用十字交叉固定(CR-Flex)和后稳定(PS-Flex)型假体接受高屈曲全膝关节置换术的患者的术后运动范围和功能结局。材料与方法在2005年至2007年间接受高屈曲全膝关节置换术的127例患者(186膝)中,CR-Flex组放置了92膝,PS-Flex组放置了94膝。术后两年的随访后,对临床和影像学资料进行了回顾。根据西安大略和麦克马斯特大学骨关节炎(WOMAC)功能子量表评估了两组患者术后膝关节的非负重范围,屈曲挛缩角度和功能结局,并在两组之间进行了比较。结果术后2年后,CR-Flex组的平均运动范围为131°,PS-Flex组的平均运动范围为133°。两组的术后运动范围无明显差异。高屈曲全膝关节置换术后仅手术年龄和术前运动范围与术后运动范围显着相关。基于WOMAC功能量表的术后功能结局在CR-Flex组(9.2±9.1分)比PS-Flex组(11.9±9.6分)稍好;然而,这种差异在统计学上不显着(p =不显着)。结论根据术后2年的高屈曲全膝关节置换术后随访,后交叉韧带的保留或替代不影响术后活动范围(ROM)或功能结局。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号