The purpose of this study was to evaluate the results of the Universal Total Wrist prosthesis. Seventeen wrist arthroplasties were performed in 15 patients using the Universal Total Wrist prosthesis. The 11 women and 4 men in the study group ranged in age from 45 to 86 years. Fourteen patients had rheumatoid arthritis and one had osteoarthritis. Follow up ranged from 20 to 74 months. Patients were evaluated for range of motion, with the Disabilities of the Arm, Shoulder, and Hand (DASH) survey and radiographically. All range of motion values improved after surgery. Average postoperative motion was 29° dorsiflexion, 38° volar flexion, 7° radial deviation and 17° ulnar deviation. The DASH scores improved with 29 %. Pain score improved in all 15 patients. One prosthesis had to be removed due to component loosening of the carpal plate. The other cases showed no radiographic signs of loosening. One patient had an early prosthetic dislocation and was treated conservatively with success.The Universal Total Wrist prosthesis provides a promising outcome in patients with rheumatoid arthritis.
机译:本研究的目的是评估通用全腕假体的结果。使用通用全腕假体对15例患者进行了17次腕关节置换术。研究组中的11名女性和4名男性的年龄从45岁到86岁不等。 14名患者患有类风湿关节炎,其中1名患有骨关节炎。随访时间为20到74个月。通过手臂,肩部和手部残疾(DASH)调查和X射线照相术评估患者的运动范围。手术后所有运动值范围均得到改善。术后平均运动为背屈29°,掌侧屈38°,radial骨偏离7°和尺骨偏离17°。 DASH分数提高了29%。 15例患者的疼痛评分均得到改善。由于腕板的部件松动,必须去除一个假体。其他病例未显示影像学上的松动迹象。一名患者早期假体脱位,并成功接受了保守治疗。通用全腕假体为类风湿关节炎患者提供了有希望的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号