摘要

Borehole thermal resistance in Ground Heat Exchanger (GHE) installations is affected by several parameters such as geometrical attributes of heat exchanger in the borehole, pipes' characteristics and grout’s thermal conductivity. A study is carried out to compare the values computed by Ground Loop Design (GLD) Software, GLD 2009, with three ana-lytical solutions for U-shaped tubes. The analysis is focused on dimensionless ratios of borehole geometrical parameters (borehole diameter to outside pipe diameter and shank spacing to borehole diameter) and pipes according to Standard Di-mension Ratio (SDR) and on eight common grouts. Finally, the effect of heat conduction in the borehole is examined by means of finite element analysis by Heat Transfer Module of COMSOL Multiphysics. A two-dimensional (2-D) steady-state simulation is done assuming working fluid temperatures for winter and summer conditions and typical Greek undis-turbed ground temperature in a field of four ground vertical U-tube heat exchangers surrounded by infinite ground. The temperature profile is presented and the total conductive heat flux from the pipe to the borehole wall per meter of length of ground heat exchanger is computed for pipes SDR11 (the outside diameter of the pipe is 11 times the thickness of its wall), SDR9 and SDR17 for summer working conditions and three different configurations. It is attempted to reach to comparative results for borehole thermal resistance value through different types of analysis, having considered the major factors that affect it and giving trends for the influence of each factor to the magnitude of its value.
机译:地面换热器(GHE)装置中的井眼热阻受多个参数的影响,例如井眼中的热交换器的几何属性,管道的特性和灌浆的热导率。进行了一项研究,以比较由接地回路设计(GLD)软件(GLD 2009)计算的值与U型管的三种分析解决方案。分析的重点是根据标准尺寸比(SDR)的钻孔几何参数(钻孔直径与外管直径以及刀柄间距与钻孔直径)的无量纲比以及八个普通灌浆。最后,通过COMSOL Multiphysics传热模块的有限元分析,检查了井眼中的导热效果。进行了二维(2-D)稳态仿真,假设冬季和夏季条件下的工作流体温度以及在被无限地面包围的四个地面垂直U型换热器场中典型的希腊不受干扰的地面温度。给出了温度曲线,并计算了管道SDR11(管道的外径是其壁厚的11倍),SDR9和从管道到钻孔热交换器每米长度的总热传导通量。 SDR17适用于夏季工作条件和三种不同配置。试图通过不同类型的分析来获得井眼热阻值的比较结果,同时考虑了影响井眼热阻值的主要因素,并给出每种因素对其值的大小的影响趋势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号