Impact of the Arterial Input Function Recording Method on Kinetic Parameters in Small-Animal PET

机译:动脉输入功能记录方法对小动物PET动力学参数的影响

获取原文
           

摘要

The goal of this study was to validate the use of an MR-compatible blood sampler (BS) with a detector system based on a lutetium oxyorthosilicate scintillator and avalanche photodiodes for small-animal PET. Methods: Five rats underwent a 60-min 18F-FDG study. For each animal, the arterial input function (AIF) was derived from the BS recording, from manual sampling (MS), and from the PET image. These AIFs were applied for kinetic modeling of the striatum using the irreversible 2-tissue-compartment model. The MS-based technique with a dispersion correction served as a reference approach, and the kinetic parameters that were estimated with the BS- and the image-derived AIFs were compared with the reference values. Additionally, the effect of applying a population-based activity ratio for plasma to whole blood (p/wb) and the dispersion correction was assessed. Results: The K1, k2, and k3 values estimated with the reference approach were 0.174 ± 0.037 mL/min/cm3, 0.342 ± 0.080 1/min, and 0.048 ± 0.009 1/min, respectively. The corresponding parameters obtained with the BS- and image-derived AIFs deviated from these values by 0.6%–18.8% and 16.7%–47.9%, respectively. To compensate for the error in the BS-based technique, data from one MS collected at the end of the experiment were combined with the data from the first 10 min of the BS recording. This approach reduced the deviation in the kinetic parameters to 1.8%–6.3%. Using p/wb led to a 1.7%–8.3% difference from the reference parameters. The sensitivity of the BS was 23%, the energy resolution for the 511-keV photopeak was 19%, and the timing resolution was 11.2 ns. Conclusion: Online recording of the blood activity level with the BS allows precise measurement of AIF, without loss of blood volume. Combining the BS data with one MS is the most accurate approach for the data analysis. The high sensitivity of the device may allow application of lower radioactivity doses.
机译:这项研究的目的是验证具有MR兼容性的血液采样器(BS)与基于正硅酸a闪烁体和雪崩光电二极管的探测器系统的结合,以用于小动物PET。方法:五只大鼠进行了60分钟的18F-FDG研究。对于每只动物,动脉输入函数(AIF)均来自BS记录,手动采样(MS)和PET图像。这些AIF使用不可逆的2组织隔室模型对纹状体进行动力学建模。具有色散校正的基于MS的技术用作参考方法,并将使用BS和图像得出的AIF估算的动力学参数与参考值进行了比较。另外,评估了对血浆和全血应用基于人群的活性比(p / wb)和分散校正的效果。结果:使用参考方法估算的K1,k2和k3值分别为0.174±0.037 mL / min / cm3、0.342±0.080 1 / min和0.048±0.009 1 / min。用BS和图像衍生的AIF获得的相应参数分别偏离这些值0.6%–18.8%和16.7%–47.9%。为了补偿基于BS的技术中的错误,将在实验结束时收集的来自一个MS的数据与来自BS记录的前10分钟的数据进行合并。这种方法可以将动力学参数的偏差降低到1.8%–6.3%。使用p / wb导致与参考参数相差1.7%–8.3%。 BS的灵敏度为23%,511-keV光电峰值的能量分辨率为19%,时序分辨率为11.2 ns。结论:使用BS在线记录血液活动水平可以精确测量AIF,而不会损失血容量。将BS数据与一个MS相结合是进行数据分析的最准确方法。设备的高灵敏度可以允许使用较低的放射性剂量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号