...
首页> 外文期刊>The Journal of Advanced Prosthodontics >Effect of soldering techniques and gap distance on tensile strength of soldered Ni-Cr alloy joint
【24h】

Effect of soldering techniques and gap distance on tensile strength of soldered Ni-Cr alloy joint

机译:焊接工艺和间隙距离对Ni-Cr合金焊接接头抗拉强度的影响

获取原文
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE The present study was intended to evaluate the effect of soldering techniques with infrared ray and gas torch under different gap distances (0.3 mm and 0.5 mm) on the tensile strength and surface porosity formation in Ni-Cr base metal alloy. MATERIALS AND METHODS Thirty five dumbbell shaped Ni-Cr alloy specimens were prepared and assigned to 5 groups according to the soldering method and the gap distance. For the soldering methods, gas torch (G group) and infrared ray (IR group) were compared and each group was subdivided by corresponding gap distance (0.3 mm: G3 and IR3, 0.5 mm: G5, IR5). Specimens of the experimental groups were sectioned in the middle with a diamond disk and embedded in solder blocks according to the predetermined distance. As a control group, 7 specimens were prepared without sectioning or soldering. After the soldering procedure, a tensile strength test was performed using universal testing machine at a crosshead speed 1 mm/min. The proportions of porosity on the fractured surface were calculated on the images acquired through the scanning electronic microscope. RESULTS Every specimen of G3, G5, IR3 and IR5 was fractured on the solder joint area. However, there was no significant difference between the test groups ( P > .05). There was a negative correlation between porosity formation and tensile strength in all the specimens in the test groups ( P CONCLUSION There was no significant difference in ultimate tensile strength of joints and porosity formations between the gas-oxygen torch soldering and infrared ray soldering technique or between the gap distance of 0.3 mm and 0.5 mm.
机译:目的本研究旨在评估在不同间隙距离(0.3 mm和0.5 mm)下使用红外线和气体焊枪进行的焊接技术对Ni-Cr基金属合金的拉伸强度和表面孔隙形成的影响。材料与方法制备了35个哑铃形Ni-Cr合金试样,并根据焊接方法和间隙距离分为5组。对于焊接方法,将焊炬(G组)和红外线(IR组)进行比较,然后将每个组细分为相应的间隙距离(0.3毫米:G3和IR3,0.5毫米:G5,IR5)。实验组的样品在中间用金刚石盘切开,并根据预定距离嵌入焊料块中。作为对照组,准备了7个标本,没有切片或焊接。焊接后,使用万能试验机以1mm / min的十字头速度进行拉伸强度试验。在通过扫描电子显微镜获得的图像上计算断裂表面上的孔隙率。结果G3,G5,IR3和IR5的每个试样在焊点区域均断裂。然而,测试组之间没有显着差异(P> .05)。试验组的所有样品的孔隙形成与拉伸强度之间均呈负相关(P结论。间隙距离为0.3毫米和0.5毫米。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号