Effect of Connector Design on Fracture Resistance in Zirconia-based Fixed Partial Dentures for Upper Anterior Region

机译:接头设计对上前区氧化锆基固定局部义齿的抗断裂性的影响

获取原文
   

获取外文期刊封面封底 >>

       

摘要

The purpose of this study was to investigate the influence of the cross-sectional form and area of the connector on fracture resistance in three-unit zirconia fixed partial denture (FPD) frameworks for the upper anterior region. Sixty FPD framework specimens were fabricated using the CAD/CAM system. The cross-sectional form (Type I, II, or III) and area (9.0, 7.0, 5.0, or 3.0 mm2) of the connectors differed. The specimens were fixed to a jig capable of applying a load axially to the abutment teeth at an angle of 135 degrees. Each specimen was subjected to fracture load measurements using a universal testing machine and cross-sectional microscopic examination. Fracture load fell significantly with a decrease in cross-sectional area (p 5.0 mm2.
机译:这项研究的目的是调查连接器的横截面形状和面积对上部前区三单元氧化锆固定局部义齿(FPD)框架中抗断裂性的影响。使用CAD / CAM系统制造了60个FPD框架标本。连接器的横截面形状(I,II或III型)和面积(9.0、7.0、5.0或3.0 mm2)不同。将样品固定在夹具上,该夹具能够以135度的角度轴向向基牙施加载荷。使用通用测试机和横截面显微镜检查对每个样品进行断裂载荷测量。断裂载荷随着截面积的减小而显着下降(p 5.0 mm2。