首页> 外文期刊>Technical Gazette >Tests of IEEE 1588-based synchronization system in substation
【24h】

Tests of IEEE 1588-based synchronization system in substation

机译:基于IEEE 1588的同步系统在变电站中的测试

获取原文
           

摘要

As a synchronization method, IEEE1588 standard has been applied in substation, it should be tested and verified ensure synchronization accuracy and node interoperability. A comprehensive testing method for the IEEE1588 is proposed in this paper. Furthermore, IEEE1588 clock testing platform is built to support the proposed testing method. Based on the analysis of the clock synchronization error and the performance testing principle method, the accuracy and stability of master clock and slave clock were evaluated. Secondly, the conformance testing to adopt performance response was achieved by designed specific case, based on the above, and then to analyse the conformance implementation details. According to testing requirements, test bed designed. Finally, the experiment based on substation devices was carried out using the IEEE1588 clock testing platform. The feasibility of the proposed methods was further verified with the testing results.
机译:作为一种同步方法,IEEE1588标准已在变电站中应用,应对其进行测试和验证,以确保同步精度和节点互操作性。本文提出了一种针对IEEE1588的综合测试方法。此外,构建了IEEE1588时钟测试平台以支持所提出的测试方法。在分析时钟同步误差和性能测试原理方法的基础上,评估了主时钟和从时钟的准确性和稳定性。其次,在上述基础上,通过设计具体案例,实现了采用性能响应的一致性测试,然后对一致性实现细节进行了分析。根据测试要求,设计测试台。最后,使用IEEE1588时钟测试平台进行了基于变电站设备的实验。测试结果进一步验证了所提方法的可行性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号