Measuring process of acoustic quality parameters in sound control room in order to determine the best setup is described. Measurements of six sound control rooms impulse response have been made. The measurements are executed in accordance with the standard ISO3382. In all sound control rooms the same measurement method is used, but the measurement setups are changed. In the first scenario built-in monitor loudspeakers were used. In the second scenario, omnidirectional sound source was used. Omnidirectional measuring microphone and an artificial head were used as receivers. They were placed at the optimal listening position. Principal components analysis method is used to get the most accurate result from measured data obtained under different scenarios and measuring setups. Hence, the measuring conditions and setups which determine the value of subjective assessments of the sound control room are obtained. The results shall be used to calculate correlation between objective measurements and subjective assessments.
机译:描述了在声控室中测量声音质量参数以确定最佳设置的过程。已对六个声音控制室的脉冲响应进行了测量。根据标准ISO3382执行测量。在所有声音控制室中,都使用相同的测量方法,但是测量设置已更改。在第一种情况下,使用了内置监听扬声器。在第二种情况下,使用了全向声源。全向测量麦克风和一个人造头被用作接收器。他们被放置在最佳聆听位置。主成分分析方法用于从不同情况和测量设置下获得的测量数据中获得最准确的结果。因此,获得了确定声控室的主观评估值的测量条件和设置。结果应用于计算客观测量和主观评估之间的相关性。