首页> 外文期刊>Quimica nova >ELEMENTARY CHARACTERIZATION OF RICE HUSK AND THEIR ASHES BY MIP OES AFTER ACID DECOMPOSITION WITH REFLUX SYSTEM
【24h】

ELEMENTARY CHARACTERIZATION OF RICE HUSK AND THEIR ASHES BY MIP OES AFTER ACID DECOMPOSITION WITH REFLUX SYSTEM

机译:回流系统酸分解后MIP OES对稻壳及其灰分的基本表征

获取原文
获取外文期刊封面目录资料

摘要

This paper describes the optimization of a sample preparation method using response surface methodology for Al, Cd, Cu, Fe, Mg, Mn, Mo, Na, Ni and Ti determinations in samples of rice husk and rice husk ash by MIP OES. Sample preparation was performed using a reflux system adapted to the digestion tubes. This system allowed the decomposition of the samples without the necessity of replacement of the acids during this step without any loss of volatile elements. The decompositions were performed with 3.6 mL of HNO3 and 1.4 mL of H2SO4 for 205 min in a digester block at 225 oC. The detection limit for determination of respective analytes in both samples were satisfactory. The RSDs for the analytes were less than 10%. Moreover, the accuracy of the method can be verified by recovery tests, whose values ranged from 82 to 115% for husk samples and 82 to 120% for ashes. The proposed method was presented as a simple, safe and low cost procedure being suitable for sample preparation and subsequent determination of metals by MIP OES.
机译:本文介绍了使用响应表面方法优化MIP OES测定稻壳和稻壳灰样品中Al,Cd,Cu,Fe,Mg,Mn,Mo,Na,Ni和Ti的样品制备方法的优化方法。使用适合消化管的回流系统进行样品制备。该系统可以使样品分解,而在此步骤中无需更换酸,而不会损失任何挥发性元素。在225 oC的蒸煮器中,用3.6 mL HNO3和1.4 mL H2SO4分解205分钟。测定两个样品中各个分析物的检测限均令人满意。分析物的RSD小于10%。此外,该方法的准确性可以通过回收率测试加以验证,其中果壳样品的值在82%到115%之间,灰烬值在82%到120%之间。提出的方法是一种简单,安全,低成本的方法,适用于样品制备和随后通过MIP OES测定金属。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号