首页> 外文期刊>Practical Laboratory Medicine >Evaluation of Bio-Rad D-100 HbA1c analyzer against Tosoh G8 and Menarini HA-8180V
【24h】

Evaluation of Bio-Rad D-100 HbA1c analyzer against Tosoh G8 and Menarini HA-8180V

机译:针对Tosoh G8和Menarini HA-8180V的Bio-Rad D-100 HbA1c分析仪评估

获取原文
           

摘要

Objectives To evaluate the Bio-Rad D-100?, an HPLC analyzer for glycated hemoglobin (HbA 1c ) determination, and to compare its performance with the Menarini HA-8180V? and Sysmex G8?. Methods Method comparison was performed according to Clinical and Laboratory Standards Institute (CLSI) EP9-A2 guidelines. We selected 100 samples from the routine laboratory workload and analyzed them in duplicate with the three analyzers. The imprecision study was performed according to CLSI EP5-A2 guidelines for both inter-assay and intra-assay variability. Bias was assessed with external quality control material. To establish linearity, CLSI EP6-A protocol was followed. Results Method comparison (95% confidence intervals in parentheses): D-100 vs G8: Passing-Bablok regression; y=0.973(0.963–0.983)×?0.07(?0.07?0.069); r=0.9989. Bland-Altman mean difference: ?0.229%HbA 1c (?0.256: ?0.202); Relative bias plot: D-100/G8 vs D100-G8 mean ratio=0.971(0.967?0.975). D-100 vs HA-8180V: Passing-Bablok regression; y=0.944(0.932–0.958)×?0.078(0.024?0.173); r=0.9989. Bland-Altman mean difference: ?0.363%HbA 1c (?0.401: ?0.325); Relative bias plot D-100/HA-8180V vs D100-HA-8180V mean ratio=0.955(0.952?0.958). Inter-assay coefficient of variation (CV): 0.81%. Intra-assay CV: 1.04% (low level), and 0.78% (high level). Bias against target value=2.332%. Linearity: r 2 =0.998 in the concentration range 4.4?13.9%HbA 1c . Carry-over: 0.0024%. Conclusions The Bio-Rad D-100 shows good correlation with G8 and HA-8180V. There is a small proportional systematic difference (2.7% and 5.6%, respectively) in both comparisons. Inter and intra-assay CVs are both lower than the lowest CV obtained in studies performed with D-100 and other instruments.
机译:目的评估用于测定糖化血红蛋白(HbA 1c)的HPLC分析仪Bio-Rad D-100 ?,并将其与Menarini HA-8180V?的性能进行比较。和Sysmex G8?方法根据临床和实验室标准协会(CLSI)EP9-A2指南进行方法比较。我们从常规实验室工作量中选择了100个样品,并使用三台分析仪进行了一式两份的分析。根据CLSI EP5-A2指南对批间和批内变异性进行不精确性研究。使用外部质量控制材料评估偏差。为了建立线性关系,遵循了CLSI EP6-A协议。结果方法比较(括号中95%的置信区间):D-100 vs G8:Passing-Bablok回归; y = 0.973(0.963-0.983)×?0.07(?0.07?0.069); r = 0.9989。布兰特-奥特曼平均差:≤0.229%HbA 1c(≤0.256:≤0.202);相对偏差图:D-100 / G8对D100-G8平均比= 0.971(0.967?0.975)。 D-100与HA-8180V:Passing-Bablok回归; y = 0.944(0.932-0.958)×?0.078(0.024?0.173); r = 0.9989。 Bland-Altman平均差异:0.363%HbA 1c(0.401:0.325);相对偏差图D-100 / HA-8180V与D100-HA-8180V的平均比= 0.955(0.952-0.958)。批间变异系数(CV):0.81%。批内CV:1.04%(低水平)和0.78%(高水平)。相对于目标值的偏差= 2.332%。线性:在浓度范围4.4≤13.9%HbA 1c时,r 2 = 0.998。结转率:0.0024%结论Bio-Rad D-100与G8和HA-8180V具有良好的相关性。在两个比较中,比例系统差异很小(分别为2.7%和5.6%)。批间和批内CV均低于使用D-100和其他仪器进行的研究中获得的最低CV。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号