Objectives To compare cine MR b-TFE sequences acquired before and after gadolinium injection, on a 3T scanner with a parallel RF transmission technique in order to potentially improve scanning time efficiency when evaluating LV function. Methods 25 consecutive patients scheduled for a cardiac MRI were prospectively included and had their b-TFE cine sequences acquired before and right after gadobutrol injection. Images were assessed qualitatively (overall image quality, LV edge sharpness, artifacts and LV wall motion) and quantitatively with measurement of LVEF, LV mass, and telediastolic volume and contrast-to-noise ratio (CNR) between the myocardium and the cardiac chamber. Statistical analysis was conducted using a Bayesian paradigm. Results No difference was found before or after injection for the LVEF, LV mass and telediastolic volume evaluations. Overall image quality and CNR were significantly lower after injection (estimated coefficient cine after cine before gadolinium: -1.75 CI = [-3.78;-0.0305], prob(coef0) = 0% and -0.23 CI = [-0.49;0.04], prob(coef0) = 4%) respectively), but this decrease did not affect the visual assessment of LV wall motion (cine after cine before gadolinium: -1.46 CI = [-4.72;1.13], prob(coef0) = 15%). Conclusions In 3T cardiac MRI acquired with parallel RF transmission technique, qualitative and quantitative assessment of LV function can reliably be performed with cine sequences acquired after gadolinium injection, despite a significant decrease in the CNR and the overall image quality.
机译:目的为了比较评估injection功能时在3T扫描仪上使用并行RF传输技术在compare注射前后获得的电影MR b-TFE序列进行比较的可能性。方法前瞻性地纳入连续25例行心脏MRI检查的患者,并在注射gadobutrol之前和之后立即获取其b-TFE电影序列。对图像进行定性评估(整体图像质量,LV边缘清晰度,伪影和LV壁运动),并通过测量LVEF,LV质量,舒张期舒张容积和心肌与心腔之间的对比噪声比(CNR)进行定量评估。使用贝叶斯范式进行统计分析。结果LVEF,LV质量和舒张期容积评估在注射前后均无差异。注射后总体图像质量和CNR显着降低((之后的电影估计系数电影:-1.75 CI = [-3.78; -0.0305],prob(coef> 0)= 0%,-0.23 CI = [-0.49; 0.04],概率分别为(概率(coef> 0)= 4%)),但这种降低并不会影响左室壁运动的视觉评估((之后的≥cine的影片:-1.46 CI = [-4.72; 1.13],概率( coef> 0)= 15%)。结论在采用并行RF传输技术采集的3T心脏MRI中,尽管CNR和整体图像质量显着下降,但使用injection注射后采集的电影序列可以可靠地进行LV功能的定性和定量评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号