首页> 外文期刊>Plasma and Fusion Research >Spectroscopic Diagnostics for Spatial Density Distribution of Plasmoid by Pellet Injection in the Large Helical Device
【24h】

Spectroscopic Diagnostics for Spatial Density Distribution of Plasmoid by Pellet Injection in the Large Helical Device

机译:大型螺旋装置中颗粒注射的等离子体空间密度分布的光谱诊断

获取原文
   

获取外文期刊封面封底 >>

       

摘要

To investigate the behavior of a plasmoid consisting of pellet ablatant ionized by background plasma, two dimensional imaging measurements of high-speed spectroscopy have been developed using a fast camera in the Large Helical Device (LHD). The diagnostic system provides density distribution of the plasmoid. The density distribution is determined using the Stark broadening width of the Balmer-β line. Stark broadening profile can be evaluated from the intensity ratio measured using narrow-band optical filters having different full width at half maximum. Two dimensional images of the plasmoid are obtained by a fast camera connected to a bifurcated fiber scope with two objective lenses. An initial result shows that the plasmoid density is obtained within a factor of 2 by imaging measurements.
机译:为了研究由背景等离子体电离的沉淀物所构成的等离子体质的行为,已经在大型螺旋装置(LHD)中使用快速相机开发了高速光谱的二维成像测量方法。诊断系统提供血浆的密度分布。密度分布使用Balmer-β线的Stark加宽宽度确定。可以从使用具有不同的半峰全宽的窄带滤光片所测量的强度比来评估鲜明的加宽轮廓。通过连接到带有两个物镜的分叉纤维镜的快速相机获得等离子的二维图像。初步结果表明,通过成像测量可在2倍的范围内获得质体密度。