首页> 外文期刊>PCI journal >Long-Term Performance of Prestressed, Pretensioned High Strength Concrete Bridge Girders
【24h】

Long-Term Performance of Prestressed, Pretensioned High Strength Concrete Bridge Girders

机译:预应力,预张高强度混凝土桥梁的长期性能

获取原文
           

摘要

align="left">An experimental investigation of high strength concrete bridge girders was conducted. The investigation included fabrication and testing of 70 ft (21.3 m) long, 54 in. (1372 mm) deep, pretensioned,? prestressed high strength concrete bulb-tee girders. The design concrete compressive strength for the girders was 10,000 psi (69 MPa). Two girders were used to evaluate long-term static load and fatigue?? performance. Results from the girder used to determine long-term static load behavior indicated prestress losses that were significantly less than those predicted by the AASHTQ Standard. The? girder used to determine fatigue performance withstood more than 5 million cycles of fatigue loading and satisfied all serviceability requirements. Upon completion of the long-term static load and? fatigue test, measured flexural properties for both girders were adequate with respect to both design and specification requirements. Based on results from this investigation, high strength concrete bridge?? girders can be expected to perform adequately over the long term when designed and fabricated in accordance with current AASHTQ provisions.
机译:align =“ left”>进行了高强度混凝土桥梁大梁的实验研究。该调查包括制造和测试70英尺(21.3 m)长,54英寸(1372 mm)深,预紧力的产品。预应力高强度混凝土球型三通梁。大梁的设计混凝土抗压强度为10,000 psi(69 MPa)。使用两个大梁评估长期静载荷和疲劳强度。性能。用于确定长期静载荷性能的梁的结果表明,预应力损失明显小于AASHTQ标准所预测的损失。该?用于确定疲劳性能的梁承受了超过500万次的疲劳载荷循环,并满足了所有适用性要求。完成长期静态载荷后又如何?在设计和规格要求方面,疲劳试验,测量的两种大梁的弯曲性能均足够。根据调查结果,高强度混凝土桥梁?按照现行AASHTQ的规定进行设计和制造时,大梁可望长期发挥足够的性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号