Objective: To study the diagnostic accuracy of Ultrasound B scan using 10 MHz linear probe in ocular trauma.Methods: A total of 61 patients with 63 ocular injuries were assessed during July 2013 to January 2014. All patients were referred to the department of Radiology from Emergency Room since adequate clinical assessment of the fundus was impossible because of the presence of opaque ocular media. Based on radiological diagnosis, the patients were provided treatment (surgical or medical). Clinical diagnosis was confirmed during surgical procedures or clinical follow-up.Results: A total of 63 ocular injuries were examined in 61 patients. The overall sensitivity was 91.5%, Specificity was 98.87%, Positive predictive value was 87.62 and Negative predictive value was 99%.Conclusion: Ultrasound B-scan is a sensitive, non invasive and rapid way of assessing intraocular damage caused by blunt or penetrating eye injuries.doi: http://dx.doi.org/10.12669/pjms.322.9241How to cite this:Shazlee MK, Ali M, Ahmed MS, Hussain A, Hameed K, Lutfi IA, Khan MT. Diagnostic accuracy of Ultrasound B scan using 10 MHz linear probe in ocular trauma; Results from a high burden country. Pak J Med Sci. 2016;32(2):385-388. doi: http://dx.doi.org/10.12669/pjms.322.9241This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
机译:目的:研究使用10 MHz线性探头进行超声B扫描对眼外伤的诊断准确性。方法:2013年7月至2014年1月,共评估61例63眼受伤的患者。所有患者均转诊至放射科。由于眼底不透明,无法对眼底进行充分的临床评估,因此急诊室是不可能的。根据放射诊断,为患者提供了治疗(外科或医学)。结果:在61例患者中共检查了63例眼外伤。总体敏感性为91.5%,特异性为98.87%,阳性预测值为87.62,阴性预测值为99%。结论:超声B扫描是一种灵敏,无创且快速的方法,可评估钝性或穿透性眼球引起的眼内损伤受伤.doi:http://dx.doi.org/10.12669/pjms.322.9241如何引用此信息:莎兹莉MK,阿里M,艾哈迈德MS,侯赛因A,哈米德K,路透IA,汗汉10 MHz线性探头在眼外伤中进行B超检查的诊断准确性;高负担国家的结果。朴J医学。 2016; 32(2):385-388。 doi:http://dx.doi.org/10.12669/pjms.322.9241这是根据知识共享署名许可(http://creativecommons.org/licenses/by/3.0)的条款分发的开放访问文章,只要适当引用了原始作品,便可以在任何介质中不受限制地使用,分发和复制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号