A pump station is a crucial flood control facility for mitigating inundation of urban lowland areas. Securing a site to increase the capacity of a pump station or to maximize the discharge capacity of the pump sump in an urban area is difficult because of various limitations. Moreover, adding a facility to improve the pump capacity of a pump station may affect flow characteristics, e.g., unexpected increases in flow velocity and vorticity, and cause severe problems in pump station operation. To solve those problems, anti-vortex devices (AVDs) have been developed and adopted according to the appropriate design standards. The Korean design criteria for AVDs are based on experience and the standards of other countries because of the lack of adequate data on AVDs. In this study, flow in the sump was numerically simulated at various AVD heights to obtain data for improving the design and efficiency of a pump station. Consequently, the appropriate height for the AVD and changes in the flow pattern and vortex in the pump sump were determined and compared with 12 cases of inflow conditions with respect to the vertical location.
机译:泵站是缓解城市低地泛滥的关键防洪设施。由于各种局限性,难以在城市中确保场地以增加泵站的容量或使泵池的排出容量最大化。此外,增加设施以改善泵站的泵容量可能会影响流动特性,例如,流速和涡度的意外增加,并在泵站操作中引起严重问题。为了解决这些问题,已经根据适当的设计标准开发并采用了防涡流装置(AVD)。由于缺少足够的AVD数据,韩国针对AVD的设计标准是基于经验和其他国家/地区的标准。在这项研究中,在各种AVD高度上对集水槽中的流动进行了数值模拟,以获得可改善泵站设计和效率的数据。因此,确定了AVD的合适高度以及泵池中流型和涡流的变化,并将其与垂直位置的12种流入条件进行了比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号