Reliability of ultrasonic diaphragm thickness measurement in mechanically ventilated infants and children: A pilot study

机译:机械通气婴儿和儿童超声隔膜厚度测量的可靠性:一项初步研究

获取原文
       

摘要

BACKGROUND. Diaphragmatic atrophy in mechanically ventilated infants and children may be due to ventilator-induced diaphragmatic dysfunction, which could lead to extubation failure. Ultrasound may be used as a means by which diaphragmatic atrophy can be reliably identified. There are currently no data reporting on the use of ultrasound to monitor diaphragm atrophy in the paediatric population. OBJECTIVES. To assess the inter- and intra-rater reliability of using ultrasound to measure diaphragm thickness in mechanically ventilated infants and children. METHOD. Diaphragm thickness measurements were compared between two individual researchers for inter-rater reliability and between multiple measurements from a single researcher for intra-rater reliability. Measurements were compared using Intraclass correlation coefficients and Bland-Altman plots. RESULTS. Results indicated excellent reliability between measurements for both inter-and intra-rater reliability, with slightly better reliability for intra-rater compared with inter-rater reliability. Intraclass correlation coefficients for inter-rater reliability were between 0.77 and 0.98, and 0.94 for intra-rater reliability. CONCLUSION. Ultrasound measurements of diaphragm thickness can be used to reliably measure diaphragm thickness in mechanically ventilated infants and children. This modality could therefore be used as a reliable outcome measure for future clinical research studies to establish the relationship between ventilator-induced diaphragmatic atrophy and children who are at risk for extubation failure.
机译:背景。机械通气婴儿和儿童的肌萎缩可能是由于呼吸机引起的diaphragm肌功能障碍,可能导致拔管失败。超声可用作可以可靠地识别diaphragm肌萎缩的手段。目前尚无关于使用超声波监测儿科人群diaphragm肌萎缩的数据报道。目标评估在机械通气的婴儿和儿童中使用超声测量隔膜厚度时在评估者之间和评估者内部的可靠性。方法。对两个独立研究人员之间的隔膜厚度测量结果进行了评估者之间的可靠性比较,对单个研究人员的多个测量结果进行了比较,以评估评估者内部的可靠性。使用类内相关系数和Bland-Altman图比较测量结果。结果。结果表明,评估者之间和评估者内部的可靠性在测量之间具有极好的可靠性,与评估者之间的可靠性相比,评估者内部的可靠性稍好。评估者间可靠性的类内相关系数在0.77和0.98之间,评估者内可靠性的类内相关系数在0.94之间。结论。隔膜厚度的超声测量可用于可靠地测量机械通风的婴儿和儿童的隔膜厚度。因此,这种方式可以用作未来临床研究的可靠结果指标,以建立呼吸机诱发的diaphragm肌萎缩症和有拔管失败风险的儿童之间的关系。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号