首页> 外文期刊>Southern African Journal of Critical Care >Endotracheal tube verification in adult mechanically ventilated patients
【24h】

Endotracheal tube verification in adult mechanically ventilated patients

机译:成人机械通气患者的气管插管验证

获取原文
       

摘要

OBJECTIVE: To explore the methods that can be used to verify endotracheal tube (ETT) placement in adult mechanically ventilated patients. METHODS: An integrative literature search was conducted in 2012 - 2013 of research citations published in English on the topic of discussion. Electronic databases searched were: the Cumulative Index of Nursing and Allied Health (CINAHL), MEDLINE, PubMed, the Joanna Briggs Institute (JBI) systematic review library, the Cochrane Library and the National Guidelines Clearinghouse. In addition, reference lists of articles, conference summaries and hand searching was performed. Citations were selected based on the inclusion and exclusion criteria as decided upon by the researchers. The process of critical appraisal was done by the researchers as well as an independent reviewer, all skilled in the research methodology and subject matter related to the topic of discussion. A total of 45 articles were included for critical appraisal. On completion of the critical appraisal, which was done by two independent reviewers, 34 articles were excluded and 11 articles were included in the integrative review analyses. Data were extracted following the critical appraisal process. Owing to the heterogeneity of studies, a metasynthesis could not be done. RESULTS: Based on the reviewed studies, various methods have been identified to verify ETT placement in adult mechanically ventilated patients, namely ultrasonography, the use of centimetre scale printed on the ETT, manual cuff palpation, bilateral auscultation of chest and palpation of symmetrical chest movements, oesophageal detector devices, visualisation of the ETT, use of chest X-ray, pulse oximetry and capnography. Both ultrasonography and capnography had excellent sensitivity and specificity in verifying ETT placement. CONCLUSION: Although there are various methods reported for ETT verification, the review results recommended ultrasonography and capnography as the most accurate and reliable verification methods.
机译:目的:探讨可用于验证成人机械通气患者气管插管(ETT)放置的方法。方法:在2012年至2013年进行了综合性文献检索,以英文发表关于讨论主题的研究引文。搜索的电子数据库为:护理和相关健康累积指数(CINAHL),MEDLINE,PubMed,乔安娜·布里格斯研究所(JBI)系统评价图书馆,Cochrane图书馆和国家指南信息交换所。此外,还进行了文章参考列表,会议摘要和人工搜索。根据研究人员确定的纳入和排除标准选择引文。关键评估的过程由研究人员以及独立的审阅者完成,他们均精通研究方法和与讨论主题相关的主题。总共包括45篇文章进行了严格评估。由两名独立审稿人完成的关键评估完成后,排除了34篇文章,将11篇文章纳入了综合评论分析。在关键评估过程之后提取数据。由于研究的异质性,无法进行元合成。结果:在回顾性研究的基础上,已经确定了各种方法来验证成人机械通气患者的ETT放置,即超声检查,使用ETT印制的厘米刻度,手动袖带触诊,胸部双侧听诊和对称性胸部运动触诊,食道检测器设备,ETT的可视化,胸部X射线的使用,脉搏血氧饱和度和二氧化碳图。超声和二氧化碳图在验证ETT放置方面均具有出色的敏感性和特异性。结论:尽管报告了多种用于ETT验证的方法,但评价结果推荐超声和二氧化碳图作为最准确,最可靠的验证方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号