A thermoelectric cooling module (TECM) is defined as a solid-state heat pump and present advantages (for example, no moving parts and no harmful gasses) over other refrigeration technologies. However, to optimally use TECMs as high efficient heat pumps it is crucial to understand the factors that influence the performance and efficiency of these modules during the installation design phase. This paper therefore provides a review on the installation design phase of TECMs together with the factors that influence the performance and efficiency during this phase. Information and a discussion on the hot and cold surface calculations, power supply calculations and heat sink calculations are provided in this work. The performance of the TECMs is influenced by the Joule heating effect, temperature difference over the TECMs and thermal conductance between the p-n junctions. The efficiency of the TECMs is influenced by the coefficient of performance (COP) and the method and type of control of the TECMs. These factors are discussed in detail. It is shown that the factors related to the performance and efficiency of the TECMs cannot be disregarded and must be taken into account during the installation design phase of the TECMs.  
机译:热电冷却模块(TECM)被定义为固态热泵,与其他制冷技术相比,具有优势(例如,无移动部件且无有害气体)。但是,要以最佳方式将TECM用作高效热泵,了解在安装设计阶段影响这些模块的性能和效率的因素至关重要。因此,本文对TECM的安装设计阶段以及在此阶段影响性能和效率的因素进行了回顾。这项工作提供了有关冷热表面计算,电源计算和散热片计算的信息和讨论。 TECM的性能受焦耳热效应,TECM上的温差以及p-n结之间的热导率的影响。 TECM的效率受性能系数(COP)以及TECM的控制方法和控制类型的影响。这些因素将详细讨论。结果表明,与TECM的性能和效率有关的因素不可忽视,在TECM的安装设计阶段必须予以考虑。  

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号