首页> 外文期刊>Safety and Health at Work >Characterization of Total and Size-Fractionated Manganese Exposure by Work Area in a Shipbuilding Yard
【24h】

Characterization of Total and Size-Fractionated Manganese Exposure by Work Area in a Shipbuilding Yard

机译:造船场中按工作区域划分的总锰和粒度分布锰的特征

获取原文

摘要

Abstract Background Shipbuilding involves intensive welding activities, and welders are exposed to a variety of metal fumes, including manganese, that may be associated with neurological impairments. This study aimed to characterize total and size-fractionated manganese exposure resulting from welding operations in shipbuilding work areas. Methods In this study, we characterized manganese-containing particulates with an emphasis on total mass (n?=?86, closed-face 37-mm cassette samplers) and particle size-selective mass concentrations (n?=?86, 8-stage cascade impactor samplers), particle size distributions, and a comparison of exposure levels determined using personal cassette and impactor samplers. Results Our results suggest that 67.4% of all samples were above the current American Conference of Governmental Industrial Hygienists manganese threshold limit value of 100?μg/m3 as inhalable mass. Furthermore, most of the particles containing manganese in the welding process were of the size of respirable particulates, and 90.7% of all samples exceeded the American Conference of Governmental Industrial Hygienists threshold limit value of 20?μg/m3 for respirable manganese. Conclusion The concentrations measured with the two sampler types (cassette: total mass; impactor: inhalable mass) were significantly correlated (r?=?0.964, p?
机译:摘要背景造船涉及密集的焊接活动,焊工暴露于各种金属烟雾(包括锰)中,这些金属烟雾可能与神经功能障碍有关。这项研究旨在表征造船工作区域中焊接操作产生的全部和尺寸分级的锰暴露。方法在本研究中,我们对含锰的颗粒进行了表征,重点是总质量(n == 86,封闭面37毫米盒式采样器)和颗粒大小选择性质量浓度(n == 86,八级)级联冲击取样器),粒度分布以及使用个人盒式和冲击取样器确定的暴露水平比较。结果我们的结果表明,所有样品中有67.4%高于当前的美国政府工业卫生学家会议以可吸入质量计的锰阈值限值100μg/ m3。此外,在焊接过程中,大多数含锰颗粒具有可吸入颗粒物的大小,所有样品的90.7%超过了美国政府工业卫生学家会议对可吸入锰的阈值极限值20?μg/ m3。结论用两种采样器(盒式磁带:总质量;撞击器:可吸入质量)测量的浓度显着相关(r?=?0.964,p?<?0.001),但使用盒式采样器获得的总浓度低于可吸入物。冲击取样器的浓度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号