Objective: While there is a large body of research in regards to cruciate retaining(CR) and cruciate sacrificing total condylar knee replacement, the literature is spars in regards to highly conforming polyetheylene such as the triatholon cruciate stabilising tibial insert (CS).The aim was to determine whether there is a difference in the range of motion, kinematics as well as the functional outcome for Triathlon CS and CR TKJR. Methods: A single hospital consecutive series of one surgeon between 2011 and 2013 were enrolled. Kinematic data recorded prospectively at the time of surgery utilizing imageless navigation included preoperative and post-replacement extension, gravity flexion, passive flexion and rotation. Intraoperative femoral and tibial cuts and definitive implants were also recorded. Statistically analysis performed to compare CS and CR TKJR range of motion, deformity correction, and rotation pre and post-operatively. Oxford functional scores were obtained at the final follow up. 124 patients were randomised to 71 CS and 53 CR TKJR. The demographics were comparable between the two groups. Results: No significant difference was found between the groups’ preoperative range of motion. The net gain in extension for the CS group was 5.65 degrees (4.14-7.17) and for CR 5.64 degrees (4.24-7.04, p=0.99) with no significant difference shown. Post-operative gravity flexion significantly increased in CS TKJR with 129.01 degrees (127.37130.66) compared with 126.35 degrees (124.39-128.30, p =0.04) for CR. A weak positive correlation was shown between the size of distal femoral cut and post-operative extension for both CS and CR TKJR. A weak positive correlation was also shown for the difference between the intraoperative cuts (tibial and femoral) and the size of the implants used, in relation to post-operative extension. Post-operative oxford scores at average of 3.4 year follow up comparable between groups. Conclusion: The kinematics of CS and CR TKJR are comparable. The post-operative gravity flexion achieved with CS TKJR was statistically greater than for CR TKJR. Patients perceptions at an average 3.4 year follow up were comparable.
机译:目的:尽管在十字交叉保留(CR)和牺牲十字交叉完全con突膝关节置换方面有大量研究,但有关高一致性聚乙烯(例如三氟乙烯十字交叉稳定胫骨插入物(CS))的文献很少。旨在确定铁人三项CS和CR TKJR的运动范围,运动学以及功能结果是否存在差异。方法:纳入2011年至2013年间由一名医生连续进行的单院连续检查。使用无图像导航在手术时前瞻性记录的运动学数据包括术前和置换后伸展,重力屈曲,被动屈曲和旋转。还记录了术中股骨和胫骨切口和确定的植入物。进行统计分析以比较CS和CR TKJR的运动范围,畸形校正以及术前和术后的旋转。在最后的随访中获得牛津功能评分。 124例患者被随机分为71例CS和53例CR TKJR。两组之间的人口统计学具有可比性。结果:两组患者术前运动范围之间无明显差异。 CS组伸展的净增益为5.65度(4.14-7.17),CR组为5.64度(4.24-7.04,p = 0.99),无明显差异。与CR的126.35度(124.39-128.30,p = 0.04)相比,CS TKJR的术后重力弯曲显着增加了129.01度(127.37130.66)。对于CS和CR TKJR,股骨远端切开的大小与术后伸展之间显示出弱的正相关。术中切口(胫骨和股骨)与所用植入物的尺寸之间的差异(与术后扩展相关)也显示出弱的正相关性。术后牛津平均评分为3.4年,两组之间的随访相当。结论:CS和CR TKJR的运动学相当。在统计学上,CS TKJR术后的重力屈曲比CR TKJR更大。平均随访3.4年的患者知觉相当。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号