首页> 外文期刊>Open Journal of Preventive Medicine >Assessment of Indoor Microbial Quality of Library’s Premise: Case of Central Library of the University of Yaoundé I
【24h】

Assessment of Indoor Microbial Quality of Library’s Premise: Case of Central Library of the University of Yaoundé I

机译:图书馆室内微生物质量的评估:以雅温得第一大学中央图书馆为例

获取原文
           

摘要

>Background: Good indoor air quality is important for human health and comfort, because people spend a most of their time within buildings. Microbial pollution is a key element of indoor air pollution. Bacteria and fungi growing indoors when sufficient moisture is available usually cause indoor air pollution. >Methods: This study was conducted to assess the microbial concentration and to identify the main bacteria and fungi in the indoor environment of Central Library of the University of Yaoundé I. A total of 76 samples were taken from indoor air, surfaces and mouldy books. Bioaerosol sampling and air concentration were made by passive air sampling technique using petri dishes containing different culture media and exposed for 30, 60 and 90 min in the morning and afternoon. Sampling of surfaces and mouldy books were made by rubbing using sterile swab. The identification of the isolated microorganisms was based on macroscopic, microscopic and biochemical characters. >Results: The concentrations of bacteria and fungi in the indoor environment of Central Library of the University of Yaoundé I ranged between 747 and 2324 CFU/m for the air and 40 and 500 CFU/cm2 for surfaces. In the examined area, the predominant culturable species of microflora were members of the following bacteria genera; Bacillus spp, Staphylococcus spp, Micrococcus spp, Pseudomonas spp, Rhodococcus spp, Enterobacter spp, Klebsiella spp and Escherichia spp and fungi; Aspergillus spp, Penicillium spp, Curvularia spp, Mucor spp, Cladosporium spp, Candida spp Rhodotorula spp, Fusarium spp, Trichophyton spp, Acremonium spp, Aureobasidium spp, Rhizopus spp and Chrysonilia spp. >Conclusion: High concentrations of bacteria and fungi were observed in the central library of the University of Yaoundé I. Precautions and safety measures should be taken to reduce microbial pollution at universities libraries by improving libraries ventilation and disinfection.
机译:>背景:良好的室内空气质量对于人类的健康和舒适度至关重要,因为人们将大部分时间都花在建筑物上。微生物污染是室内空气污染的关键因素。当有足够的水分时,在室内生长的细菌和真菌通常会导致室内空气污染。 >方法:该研究旨在评估雅温得I大学中央图书馆室内环境中的微生物浓度并鉴定主要细菌和真菌。共从室内空气中采集了76个样本,表面和发霉的书籍。使用包含不同培养基的培养皿,通过被动空气采样技术进行生物气溶胶采样和空气浓缩,并在早晨和下午分别暴露30、60和90分钟。通过使用无菌拭子摩擦来对表面和发霉的书籍进行采样。分离的微生物的鉴定是基于宏观,微观和生化特征。 >结果:雅温得第一大学中央图书馆室内环境中的细菌和真菌的浓度范围为空气的747和2324 CFU / m之间,表面的浓度为40和500 CFU / cm2。在检查区域,微生物群落的主要可培养物种是以下细菌属的成员。芽孢杆菌属,葡萄球菌属,微球菌属,假单胞菌属,红球菌属,肠杆菌属,克雷伯菌属和埃希氏菌属和真菌;曲霉菌属,青霉菌属,弯孢菌属,Mucor菌种,Cladosporium菌种,念珠菌菌种Rhodotorula菌种,镰刀菌属菌种,毛癣菌属菌种,顶头菌属菌种,金黄色葡萄球菌属菌种,Rhizopus菌种和Chrysonson属。 >在雅温得第一大学的中央图书馆中观察到高浓度的细菌和真菌。应采取预防措施和安全措施,通过改善图书馆的通风和消毒来减少大学图书馆中的微生物污染。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号