首页> 外文期刊>Kurume Medical Journal >Measurement of Intracranial Pressure via the Anterior Fontanelle in Infants with HydrocephalusSpecial observations on the operative indications and pathophysiology of Infantile hydrocephalus
【24h】

Measurement of Intracranial Pressure via the Anterior Fontanelle in Infants with HydrocephalusSpecial observations on the operative indications and pathophysiology of Infantile hydrocephalus

机译:脑积水婴儿通过Font门测量颅内压有关小儿脑积水的手术适应症和病理生理学的特殊观察

获取原文
           

摘要

A miniaturized paper strain gauge transducer was developed which atraumatically and continuously monitored intracranial pressure via the arterior f ontanelle of newborn infants. Using this equiment, six infants with hydrocephalus were prospectively studied to relate the change in ICP during sleep with clinical symptoms, head circumference, ventricular size by CT-scan, CSF dynamics and development. In the first group, the pulse wave amplitude increased with age and no B-type waves were observed during non-REM sleep. These patients were observed prospectively without surgical intervention, because they seemed to have an arrested hydrocephalus. In the second group, the pulse wave amplitude was extremery low and there was little increase in amplitude with age during non-REM sleep. The frequent appearance of B-type waves was demonstrated. These patients were considered to have a compensated hydrocephalus and a V-P shunting operation was performed in both of them. In the third group, the pulse wave amplitude increased with age, and a B-type wave was frequently identified during non-REM sleep. A plateau type wave was identified with a pressure more than 250 mmH2O, approximately equal to 310 mmH2O, from the serial measurement of ICP during REM sleep. There was a progression of the ventriculomegaly and a disproportionate increase in head circumference developed. Continuous atraumatic measurement of ICP during sleep may by quite useful for assessing the reserve capacity of the intracranial space in hydrocephalic infants and for determining whether a shunt should be implanted.
机译:开发了一种微型纸应变计传感器,该传感器通过新生儿的后脚趾无创地连续监测颅内压。使用该仪器,对6名患有脑积水的婴儿进行了前瞻性研究,以通过计算机断层扫描,脑脊液动力学和发育,将睡眠期间ICP的变化与临床症状,头围,心室大小联系起来。在第一组中,非快速眼动睡眠期间脉搏波幅度随年龄增加而未观察到B型波。无需手术干预即可对这些患者进行前瞻性观察,因为他们似乎患有脑积水。在第二组中,非快速眼动睡眠期间,脉搏波振幅极低,并且振幅几乎不随年龄增加。证实了B型波的频繁出现。这些患者被认为患有代偿性脑积水,并且他们俩均进行了V-P分流手术。在第三组中,脉搏波振幅随年龄增长而增加,并且在非快速眼动睡眠中经常发现B型波。根据REM睡眠期间ICP的连续测量,发现平台型波的压力大于250 mmH2O,大约等于310 mmH2O。脑室扩大,头围不成比例地增加。在睡眠期间连续进行ICP的无创伤测量可能对评估脑积水婴儿颅内空间的储备容量和确定是否应植入分流管非常有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号