Purpose: To evaluate the in vitro fracture resistance of roots with glass-fiber and metal dowels with different designs.Methods: Fifty-endodontically treated maxillary central incisors were embedded in acrylic resin. Ten of them received only the coronary preparation, and the remaining forty were embedded (except for 4mm of the cervical area) after removing the clinical crowns. Specimens were divided into five groups (n=10): control (teeth with only coronary preparation), cylindrical cast dowel, conical cast dowel, cylindrical glass-fiber dowel and conical glass-fiber dowel. Specimens were subjected to an increasing compressive load (N) until fracture.Results: ANOVA indicated significant difference (P < 0.05) among the groups, and the Tukey-Kramer's test identified these differences. The control group (867±243 N) presented the highest values and was statistically similar to cylindrical glass-fiber dowel group (711±180 N). There is no significant difference among the metal dowel cylindrical (435±245 N) or conical (585±164 N) group and conical glass-fiber dowel (453±112 N). Cylindrical glass-fiber dowel (711±180 N) and conical cast dowel and core (585±164 N) groups had intermediate values and did not differ from each other. Conclusions: Cylindrical glass fiber dowels represent a viable alternative to the cast-metal dowel cylindrical or conical. Cylindrical glass fiber dowels also increase endodontically treated incisors’ resistance to fracture.
机译:目的:评价不同设计的玻璃纤维和金属销钉对牙根的体外抗断裂性。方法:将五十种经牙髓治疗的上颌中切牙嵌入丙烯酸树脂中。其中有十只仅接受了冠状动脉制剂,其余的四十枚在去除临床冠后被埋入(宫颈区域4mm除外)。标本分为五组(n = 10):对照组(仅冠状预备牙齿),圆柱型铸造销钉,圆锥形铸造销钉,圆柱状玻璃纤维销钉和圆锥形玻璃纤维销钉。结果:ANOVA表示各组之间存在显着差异(P <0.05),而Tukey-Kramer检验确定了这些差异。对照组(867±243 N)呈现最高值,并且在统计上类似于圆柱玻璃纤维销钉组(711±180 N)。圆柱销(435±245 N)或圆锥销(585±164 N)组与圆锥形玻璃纤维销钉(453±112 N)之间没有显着差异。圆柱玻璃纤维销钉(711±180 N)和圆锥形铸造销钉和芯(585±164 N)组具有中间值,并且彼此之间没有差异。结论:圆柱形玻璃纤维销钉是圆柱形或圆锥形铸造金属销钉的可行替代品。圆柱形玻璃纤维销钉也可提高经牙髓治疗的切牙的抗断裂能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号