首页> 外文期刊>Revista Brasileira de Ortopedia >Artigo original Avalia??o radiográfica da técnica de cimenta??o com haste femoral c?nica polida e tripla cunha em artroplastia do quadril Radiographic evaluation of cementation technique using polished, conical, triple‐tapered femoral stem in hip arthroplasty ☆
【24h】

Artigo original Avalia??o radiográfica da técnica de cimenta??o com haste femoral c?nica polida e tripla cunha em artroplastia do quadril Radiographic evaluation of cementation technique using polished, conical, triple‐tapered femoral stem in hip arthroplasty ☆

机译:原始文章髋关节置换术中使用抛光的圆锥形股骨柄和三楔形骨水泥接合技术的影像学评估髋关节置换术中使用抛光的,锥形,三锥度股骨柄的接合技术放射学评估☆

获取原文
       

摘要

Objective To radiographically evaluate the quality of cementation and implantation technique using a polished, triple‐tapered femoral stem in total hip arthroplasty (THA). Method Retrospective study with radiographic evaluation of 86 hips in 83 patients who underwent to primary THA with the triple‐tapered cemented femoral stem C‐Stem (DePuy Orthopedics, Warsaw, Ind). Cases with at least one‐year of follow‐up were included, and data related to preoperative, immediate postoperative, and late postoperative radiographic evolution were recorded. This study analyzed, among others, the proximal femoral anatomy, the quality of cementation as described by Barrack, and the implant positioning. Cementation was also evaluated and quantified in the Gruen zones with one‐year of follow‐up. Results The mean age was 62.85 years. Proximal femoral anatomical conformation was Dorr type A in 34 (39.53%) cases, type B in 52 (60.46%), and no type C cases were found. Five (5.81%) cases were defined as type A by Barrack's cementation classification system, 46 (56.49%) type B, 27 (31.40%) type C, and eight (9.30%) type D. The greatest cement mantle thickness was observed in zones four (15.53 mm) and 11 (15.64 mm), and the smallest in zone nine (3.51 mm). Positioning in varus was observed in eight (9.3%) cases, valgus in 25 (29%), forward deviation in two (5%), and backward deviation in 55 (63.95%). Conclusions The C‐Stem femoral system presented satisfactory results related to cementation pattern, positioning, osteolysis, and stress shielding with regard to literature referring to double‐tapered or triple‐tapered models, demonstrating to be a safe method, with a predictable and reliable cementing pattern.
机译:目的通过影像学评估在全髋关节置换术(THA)中使用抛光的三锥度股骨柄的固井和植入技术的质量。方法回顾性研究,对83例接受三锥骨水泥股骨干C-Stem(DePuy骨科,华沙,印度)行原发性THA的患者进行了影像学评估,共83例。包括至少随访一年的病例,并记录与术前,术后即刻和术后晚期影像学演变有关的数据。这项研究分析了股骨近端解剖结构,Barrack所描述的胶结质量以及植入物的位置。在一年的随访中,还对格伦地区的胶结作用进行了评估和量化。结果平均年龄为62.85岁。股骨近端解剖构象为Dorr A型34例(39.53%),B型52例(60.46%),未发现C型。根据Barrack的胶结分类系统,有5例(5.81%)被定义为A型,B型为46(56.49%),C型为27(31.40%),D型为8(9.30%)。四个区域(15.53毫米)和11个区域(15.64毫米),而最小的九个区域(3.51毫米)。内翻定位8例(9.3%),外翻25例(29%),向前偏斜2例(5%),向后偏斜55例(63.95%)。结论对于涉及双锥或三锥模型的文献,C-Stem股骨系统在胶结模式,定位,骨溶解和应力屏蔽方面均表现出令人满意的结果,表明这是一种安全的方法,具有可预测和可靠的胶结模式。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号