首页> 外文期刊>Revista Brasileira de Ortopedia >Análise comparativa da dor em pacientes submetidos à artroplastia total do joelho em rela??o aos níveis pressóricos do torniquete pneumático ☆
【24h】

Análise comparativa da dor em pacientes submetidos à artroplastia total do joelho em rela??o aos níveis pressóricos do torniquete pneumático ☆

机译:全膝关节置换术患者的疼痛与充气止血带压力水平的比较分析☆

获取原文
           

摘要

ResumoObjetivos Avaliar, por meio da escala visual analógica (EVA), a dor em pacientes submetidos à artroplastia total do joelho (ATJ) com diferentes press?es do torniquete pneumático. Métodos Foi feito um estudo observacional, descritivo, de caráter analítico, prospectivo, randomizado, no qual 60 pacientes foram submetidos à ATJ, divididos em dois grupos, os quais foram comparados entre si: um grupo no qual a {ATJ} foi feita com press?o do torniquete de 350 mmHg (Padr?o) e outro com 100 mmHg acima da press?o arterial sistólica (P + 100). Esses pacientes tiveram sua dor aferida pela {EVA} após 48 horas, no quinto e no 15? dias após o procedimento cirúrgico. Secundariamente, foram medidos também a amplitude de movimento (ADM), o sangramento via dreno suctor e as complica??es em cada um dos grupos estudados; os dados foram submetidos à análise estatística. Resultados Após a análise dos dados, n?o foi constatada diferen?a estatisticamente significante em nível de 5% de significancia da press?o em rela??o à incidência de complica??es (p = 0,612), {ADM} (p = 0,202), ao sangramento após 24 e 48 h (p = 0,432 e p = 0,254) e à EVA. Também n?o foi constatada correla??o do tempo de isquemia em rela??o a {EVA} e ao sangramento. Conclus?es As press?es usadas do torniquete pneumático, 350 mmHg ou press?o arterial sistólica + 100 mmHg, n?o tiveram influência sobre a dor, a perda sanguínea, a amplitude de movimento e as complica??es, s?o press?es seguras que n?o alteram o resultado final, desde que respeitados o tempo da isquemia e individualizados os casos. Abstract Objectives To evaluate through the visual analogue scale (VAS) the pain in patients undergoing total knee replacement (TKR) with different pressures of the pneumatic tourniquet. Methods An observational, randomized, descriptive study on an analytical basis, with 60 patients who underwent TKR, divided into two groups, which were matched: a group where {TKR} was performed with tourniquet pressures of 350 mmHg (standard) and the other with systolic blood pressure plus 100 mmHg (P + 100). These patients had their pain assessed by {VAS} at 48 hours, and at the 5th and 15th days after procedure. Secondarily, the following were also measured: range of motion (ROM), complications, and blood drainage volume in each group; the data were subjected to statistical analysis. Results After data analysis, there was no statistical difference regarding the incidence of complications (p = 0.612), {ROM} (p = 0.202), bleeding after 24 and 48 hours (p = 0.432 and p = 0.254) or in relation to VAS. No correlation was observed between time of ischemia compared to {VAS} and bleeding. Conclusions The use of the pneumatic tourniquet pressure at 350 mmHg or systolic blood pressure plus 100 mmHg did not influence the pain, blood loss, ROM, and complications. Therefore the pressures at these levels are safe and do not change the surgery outcomes; the time of ischemia must be closely observed to avoid major complications.
机译:摘要目的使用视觉模拟量表(VAS)评估在不同气压止血带压力下进行全膝关节置换术(TKA)的患者的疼痛。方法进行观察性,描述性,分析性,前瞻性,随机性研究,将60例行TKA的患者分为两组,两组进行比较:止血带为350 mmHg(标准),另一根止血带高于收缩压100 mmHg(P + 100)。这些患者在第48和15小时的第48小时后是否通过{VAS}测量了疼痛?手术后几天。其次,还测量了每个研究组的运动范围(ROM),通过引流口的出血和并发症。对数据进行统计分析。结果分析数据后,在5%的压力显着性水平上与并发症的发生率无统计学差异(p = 0.612),{ADM}( p = 0.202),24和48 h(p = 0.432和p = 0.254)和VAS后出血。与{VAS}相关的缺血时间与出血之间也没有相关性。结论所使用的气压止血带的压力为350 mmHg或收缩压+ 100 mmHg,对疼痛,失血,运动范围和并发症没有影响,仅此而已吗?只要尊重缺血时间并根据情况进行个性化设置,安全压力就不会改变最终结果。摘要目的通过视觉模拟量表(VAS)评估在不同压力的充气止血带下进行全膝关节置换(TKR)的患者的疼痛。方法对60例行TKR的患者进行分析性观察,随机,描述性研究,将其分为两组,两组分别为:{TKR}行止血带压力为350 mmHg(标准),另一组行止血带收缩压加100 mmHg(P + 100)。这些患者在术后48小时以及术后第5天和第15天通过{VAS}进行疼痛评估。其次,还测量以下各项:每组的运动范围(ROM),并发症和血液排出量;对数据进行统计分析。结果数据分析后,并发症发生率(p = 0.612),{ROM}(p = 0.202),24和48小时后出血(p = 0.432和p = 0.254)或与VAS无关,无统计学差异。 。与{VAS}相比,缺血时间与出血之间没有相关性。结论使用350 mmHg的气压止血带或收缩压加上100 mmHg的气压不会影响疼痛,失血,ROM和并发症。因此,在这些水平上的压力是安全的,不会改变手术结果。必须密切观察缺血时间,以免出现严重并发症。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号