Objectives To evaluate bleeding and the estimated blood loss in patients who underwent total knee replacement (TKR) with different closed suction drains (3.2-mm and 4.8-mm gauge). Methods This was a randomized controlled trial with 22 patients who underwent TKR and were divided into two groups: Group I , with 11 patients in whom the 3.2-mm suction drain was used, and Group II , with 11 patients in whom the 4.8-mm suction drain was used. The hematocrit was measured after 24, 48 and 72 h after surgery in order to calculate the estimated blood loss. The drained volume was measured 3, 6, 12, 24, and 48 h after TKR, and thereafter both groups were compared. Results Regarding the hematocrit, there were no differences between groups in measured periods (24, 48, and 72 h after surgery). The total bleeding measured at the suction drains within 48 h was higher in Group II , with a statistically significant difference ( p = 0.005); in the first 24 h, there was major bleeding in Group II (mean 893 mL), with a significant difference ( p = 0.004). Between 24 and 48 h, there was no statistically significant difference in both groups ( p = 0.710). The total estimated bleeding was higher in Group I , with mean of 463 mL, versus 409 mL in Group II , with no statistical significance ( p = 0.394). Conclusions Bleeding was higher in the group that used the 4.8 mm gauge suction drain, with no differences in hematocrit and estimated blood loss.
机译:目的评估不同闭合闭合引流管(3.2 mm和4.8 mm规)进行全膝关节置换(TKR)的患者的出血情况和估计的失血量。方法这是一项随机对照试验,其中22例行TKR的患者分为两组:第一组11例使用3.2mm引流引流管;第二组11例使用4.8mm引流管。使用了抽水口。在手术后24、48和72小时后测量血细胞比容,以计算估计的失血量。在TKR后3、6、12、24和48小时测量引流量,然后将两组进行比较。结果关于血细胞比容,两组之间在测量的时间段(手术后24、48和72小时)没有差异。 II组在48小时内在抽水口处测得的总出血量较高,差异具有统计学意义(p = 0.005);在最初的24小时内,第二组有大量出血(平均893 mL),差异有统计学意义(p = 0.004)。在24至48小时之间,两组均无统计学差异(p = 0.710)。第一组的总估计出血量较高,平均为463 mL,而第二组的总出血量则为409 mL,无统计学意义(p = 0.394)。结论在使用4.8 mm规格的引流管的组中,出血量较高,血细胞比容和估计失血量无差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号