...
首页> 外文期刊>Revista Brasileira de Medicina do Esporte >Compara??o entre os métodos direto e indireto de determina??o do VO 2máx de praticantes de corrida
【24h】

Compara??o entre os métodos direto e indireto de determina??o do VO 2máx de praticantes de corrida

机译:直接和间接测定跑步者VO 2max方法的比较

获取原文
           

摘要

KRAVCHYCHYN, Ana Claudia Pelissari et al. Comparison between the direct and indirect methods of VO2máxdetermination in runners. Rev Bras Med Esporte [online]. 2015, vol.21, n.1, pp.17-21. ISSN 1517-8692.? http://dx.doi.org/10.1590/1517-86922015210101412.INTRODUCTION: direct tests are considered "gold standard" for determining physiological variables. However, the financial cost is high and there is the need of skilled labor for its operation. Thus, the indirect tests are used by most professional of Physical Education as an affordable alternative to the lack of direct measurement.OBJECTIVE: to compare the values of maximum consumption of oxygen (VO2max), determined directly by a system with spirometry values determined from indirect protocols.METHODS: 15 male individuals participated (27.4 ± 3.5 years), physically active, who performed the incremental test on treadmill for the direct determination of VO2max with the gas analyzer. The tests for the prediction of VO2max were ErgoPC; Polar Fitness Test, test bank and Cooper. We used descriptive statistics (mean ± standard deviation - SD); the sphericity was tested by Mauchly's test, the methods were compared by ANOVA of repeated measurements, with Bonferroni adjustment for multiple comparisons. Data normality was evaluated by the Shapiro-Wilk test, and the Pearson correlation coefficient was also applied, adopting a significance level of p <0.05.RESULTS: the average VO2max was determined directly from 55.8 ± 6.1 ml ? kg -1 ? min-1 and the values for the indirect tests, the percentage of underestimation and correlation coefficient were, respectively: 33.7 ErgoPc ± 4.5 ml ? kg -1 ? min-1(39.6%, r = 0.71, p <0.001); Polar Fitness Test 53.2 ± 6.4 ml ? kg -1 ? min-1(4.6%, r = 0.64, p = 0.774); bank test 48.8 ± 6.3 ml ? kg -1 ? min-1 (12.5%, r = 0.60, p = 0.001 ) and Cooper 43.9 ± 7.9 ml ? kg -1? min-1 (21.4%, r = 0.65, p <0.001).CONCLUSION: the indirect methods may suggest overload in lower or higher training for required physiological adaptations and only the Polar Fitness Test showed no difference statistically significant.
机译:KRAVCHYCHYN,Ana Claudia Pelissari等。跑步者体内VO2直接和间接测定方法的比较。 Rev Bras Med Esporte [在线]。 2015,vol.21,n.1,pp.17-21。 ISSN 1517-8692。? http://dx.doi.org/10.1590/1517-86922015210101101412。引言:直接测试被认为是确定生理变量的“黄金标准”。但是,财务成本很高,并且需要熟练的劳动力来进行操作。因此,大多数体育专业人士都可以使用间接测试来代替缺乏直接测量的负担得起的方法。目的:比较由系统直接确定的最大耗氧量(VO2max)值与间接测定的肺活量值方法:方法:15名男性参与者(27.4±3.5岁),身体活动,他们在跑步机上进行了增量测试,用气体分析仪直接测定VO2max。预测最大摄氧量的测试方法是ErgoPC。 Polar体能测试,测试库和Cooper。我们使用描述性统计量(均值±标准差-SD);球形度通过Mauchly检验进行了测试,方法通过重复测量的ANOVA进行了比较,其中Bonferroni调整用于多次比较。通过Shapiro-Wilk检验评估数据的正态性,并应用Pearson相关系数,显着性水平为p <0.05。结果:直接从55.8±6.1 ml?确定平均VO2max?千克-1 min-1和间接测试的值,被低估的百分比和相关系数分别为:33.7 ErgoPc±4.5 ml?千克-1 min-1(39.6%,r = 0.71,p <0.001);极地适应性测试53.2±6.4毫升千克-1 min-1(4.6%,r = 0.64,p = 0.774);银行测试48.8±6.3毫升千克-1 min-1(12.5%,r = 0.60,p = 0.001)和Cooper 43.9±7.9 ml?千克-1? min-1(21.4%,r = 0.65,p <0.001)。结论:间接方法可能提示为适应所需的生理适应性,在较低或较高水平的训练中会超负荷,只有极地适应性试验没有统计学差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号