...
首页> 外文期刊>Revista Brasileira de Anestesiologia >Comparison of effectiveness of intubation by way of 'Gum Elastic Bougie' and 'Intubating Laryngeal Mask Airway' in endotracheal intubation of patients with simulated cervical trauma
【24h】

Comparison of effectiveness of intubation by way of 'Gum Elastic Bougie' and 'Intubating Laryngeal Mask Airway' in endotracheal intubation of patients with simulated cervical trauma

机译:比较“胶弹弹弓”和“插入喉罩气道”插管在模拟宫颈外伤患者气管插管中的有效性

获取原文
           

摘要

SUT, Esra Yildiz; GUNAL, Solmaz; YAZAR, Mehmet Akif ?and? DIKMEN, Beyazit. Comparison of effectiveness of intubation by way of "Gum Elastic Bougie" and "Intubating Laryngeal Mask Airway" in endotracheal intubation of patients with simulated cervical trauma. Rev. Bras. Anestesiol. [online]. 2017, vol.67, n.3, pp.238-245. ISSN 0034-7094.? http://dx.doi.org/10.1016/j.bjane.2016.03.001. Purpose: In this study, we evaluated the effectiveness of intubations by way of "Gum Elastic Bougie" and "Intubating Laryngeal Mask Airway" in endotracheal intubation of patients with simulated cervical trauma. Method: 134 patients were included in the study. All patients were placed cervical collar for a simulated cervical trauma. Patients were allocated randomly into three groups: Group NI (n = 45) intubation with Macintosh laryngoscopy, Group GEB (n = 45) intubation with Gum Elastic Bougie, and Group ILMA (n = 44) intubation with Intubating Laryngeal Mask Airway. The number of intubation attempts, success of intubation, duration of complete visualization of the larynx, duration of intubation, user's performance score, hemodynamic changes and the observed complications were recorded. Results: Success of intubation in the first attempt was highest in Group GEB while it was lowest in Group ILMA. Regarding the intubation success, rates of successful intubation were 95.6%, 84.4% and 65.9% in Groups GEB, NI, and ILMA, respectively. Durations of visualization of larynx and intubation were shorter in Groups NI and GEB than in Group ILMA. This difference was statistically significant (p < 0.05) while there was no significant difference between Groups NI and GEB. The number of patients with "good" intubation performance was significantly higher in Group GEB while the number of patients with "poor" intubation performance was significantly higher in Group ILMA (p < 0.05). Conclusions: We conclude that GEB, which is cheap and easily accessible, should be an advantageous choice in cervical trauma patients for both the easeness of intubation and patient morbidity and mortality.
机译:SUT,埃斯拉·耶尔迪兹(Esra Yildiz); GUNAL,Solmaz; YAZAR,穆罕默德·阿基夫(Mohmet Akif)?迪克曼,贝亚兹。比较“胶弹弹弓”和“喉罩气道插管”在模拟宫颈外伤患者气管插管中的效果。胸罩牧师茴香醚。 [线上]。 2017年,第67卷,第3期,第238-245页。 ISSN 0034-7094。? http://dx.doi.org/10.1016/j.bjane.2016.03.001。目的:在这项研究中,我们评估了通过“口香糖弹性弹药”和“插入喉罩气道”进行插管在模拟宫颈外伤患者气管插管中的有效性。方法:134名患者被纳入研究。将所有患者放置在颈环上,以模拟颈椎创伤。将患者随机分为三组:使用Macintosh喉镜检查的NI组(n = 45)插管,使用口香糖弹性Bougie的GEB组(n = 45)插管和使用喉罩气管插管的ILMA组(n = 44)插管。记录插管尝试次数,插管成功率,喉部完全可视化持续时间,插管持续时间,使用者的表现评分,血液动力学变化和观察到的并发症。结果:首次插管成功率在GEB组中最高,而在ILMA组中最低。关于插管成功率,GEB,NI和ILMA组的插管成功率分别为95.6%,84.4%和65.9%。 NI和GEB组的喉和插管可视化持续时间短于ILMA组。 NI和GEB组之间无统计学差异(p <0.05)。 GEB组中具有“良好”插管性能的患者数量显着更高,而ILMA组中具有“较差”插管性能的患者数量则显着更高(p <0.05)。结论:我们得出的结论是,便宜且易于获得的GEB对于宫颈外伤患者而言应是插管的简便性以及患者发病率和死亡率的一个有利选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号