Assessment of Physicochemical Parameters of Tubing's of Intravenous Infusion sets

机译:静脉输液器油管的理化参数评估

获取原文
           

摘要

The main objectives of study were to evaluate the physicochemical test of the leachates of Intravenous infusion sets of seven brands used in thepresent study were purchased from different medical shops in Lucknow. At 60-2-C for 2 hours condition, the maximum global migration residue was found from IV-6 sample in 5% sodium carbonate (6.2 mg/100 ml) while the minimum was in IV-5 sample in 3% acetic acid (0.2 mg/100 ml) (Fig.1). The results also showed that at 25-2-C for 24 hours condition, the maximum global migration residue was found from IV-6 sample in 0.9% sodium chloride (5.2 mg/100 ml) while the minimum was in IV-5 sample in 3% acetic acid (0.14 mg/100 ml) (Fig.2). The results revealed that at 60-2-C for 2 hours condition, the maximum migration of oxidizable matters was from the leachates of IV-3 sample in double distilled water (3 ml; difference in the volume of sodium thiosulphate consumed) while the minimum migration of oxidizable matters was observed in IV-4 and IV-5 sample in sodium carbonate (0.1 ml) (Fig 3). At 25-2-C for 24 hours condition, the maximum migration of oxidizable matters was from the leachates of IV-3 sample in double distilled water (2.3 ml; difference in the volume of sodium thiosulphate consumed) while the minimum migration of oxidizable matters was observed in IV-2, IV-4, IV-5 and IV-7 sample in sodium carbonate (Fig. 4). At 60-2-C for 2 hours condition, the maximum migration of UV absorbing materials was from IV-1 sample in 0.3% acetic acid (OD - 0.206) whiles the minimum was from IV-5 sample in 0.9% sodium chloride (OD - 0.035). The migration was below the permissible limit (OD - 0.3) (Fig. 5). At 25-2-C for 24 hours condition, the maximum migration of UV absorbing materials was from IV-1 sample in 0.3% acetic acid (OD - 0.161) whiles the minimum was from IV-5 sample in 0.9% sodium chloride (OD - 0.031). The migration was below the permissible limit (OD - 0.3) (Fig. 6). The results showed that the leaching of additives used in plastic biomedical devices is temperature dependent i.e. high at higher temperature. These additives are not chemically bound to the matrix of the polymeric materials and leach out during normal use.
机译:研究的主要目的是评估本研究中使用的七个品牌的静脉输液器的渗滤液的理化测试,这些渗出液是从勒克瑙的不同医疗商店购买的。在60-2-C下2小时的条件下,在5%碳酸钠(6.2 mg / 100 ml)中的IV-6样品中发现了最大的总体迁移残留物,而在3%乙酸中的IV-5样品中发现了最小的整体迁移残留物( 0.2 mg / 100 ml)(图1)。结果还显示,在25-2-C下24小时的条件下,在0.9%氯化钠(5.2 mg / 100 ml)中的IV-6样品中发现了最大的总体迁移残留物,而在IV-5样品中在IV-5样品中发现了最大的整体迁移残留物。 3%乙酸(0.14 mg / 100 ml)(图2)。结果显示,在60-2-C下2小时的条件下,可氧化物质的最大迁移来自IV-3样品在双重蒸馏水中(3 ml;硫代硫酸钠消耗量之差)的浸出液,而最小在碳酸钠(0.1 ml)中的IV-4和IV-5样品中观察到可氧化物质的迁移(图3)。在25-2-C下24小时的条件下,可氧化物质的最大迁移来自IV-3样品在双重蒸馏水中的沥出液(2.3 ml;消耗的硫代硫酸钠的体积差异),而可氧化物质的最小迁移在碳酸钠中的IV-2,IV-4,IV-5和IV-7样品中观察到了这种现象(图4)。在60-2-C下2小时的条件下,紫外线吸收材料的最大迁移来自于IV-1样品在0.3%的乙酸中(OD-0.206),而最小的是来自IV-5样品在0.9%氯化钠(OD)中的迁移-0.035)。迁移低于容许极限(OD-0.3)(图5)。在25-2-C下24小时的条件下,紫外线吸收材料的最大迁移来自于IV-1样品在0.3%的乙酸中(OD-0.161),而最小的是来自IV-5样品在0.9%氯化钠(OD)中的迁移-0.031)。迁移低于容许极限(OD-0.3)(图6)。结果表明,用于塑料生物医学装置的添加剂的浸出是温度依赖性的,即在较高温度下较高。这些添加剂不会化学键合到聚合材料的基质上,在正常使用过程中会浸出。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号