The use of Ni-Ti alloy in medical applications gave a great importance for the right composition of this alloy and the method of fabricating this alloy parts. Medical implants should be tested to assure that there are no defects or imperfections included and so no harmful effects could take place. In this study different Ni-Ti alloy composition samples have been fabricated using three different techniques. These techniques are sand casting, powder-sand casting method and sintering method. A comparison between samples made in by each technique was made. Surface and subsurface defects found in these fabricated samples have been investigated using non- destructive techniques. These non-destructive techniques used were die penetrant testing, electromagnetic method and finally samples were inspected using ultrasonic waves. Based on the results of surface and subsurface non-destructive tests used, samples prepared using sand casting were found to have the lowest surface and subsurface defects and so it is highly recommended to fabricate Ni-Ti alloy implants.
机译:Ni-Ti合金在医学应用中的使用对于这种合金的正确组成以及该合金零件的制造方法非常重要。应该对医疗植入物进行测试,以确保其中没有缺陷或瑕疵,因此不会发生有害影响。在这项研究中,使用三种不同的技术制作了不同的Ni-Ti合金成分样品。这些技术是砂型铸造,粉末砂型铸造法和烧结法。比较每种技术制备的样品。已使用非破坏性技术研究了在这些人造样品中发现的表面和亚表面缺陷。使用的这些非破坏性技术是模头渗透测试,电磁法,最后使用超声波检查样品。根据所使用的表面和亚表面无损检测的结果,发现使用砂型铸造制备的样品具有最低的表面和亚表面缺陷,因此强烈建议制造Ni-Ti合金植入物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号