Preliminary Evaluation of Indoor Radon Exposure Levels in Students' Halls of Residence at the Northern Campus (New Site) of the University of Cape Coast, Ghana

机译:加纳海角海岸大学北校区(新址)学生宿舍室内室内Rad暴露水平的初步评估

获取原文
           

摘要

The study seeks to present Radon exposure levels in some rooms within halls of residence at the New Site of the University of Cape Coast, Ghana determined using LR-115 TypeII Solid State Nuclear Track Detector (SSNTD) and E-PERM detecting systems. Pieces of the plastic LR-115 detectors were covered with aluminium foil and fixed in plastic holder such that the active part (coated part) of the detector was exposed (bare), facing downwards and together with the E-PERM were placed at a location in each of the selected rooms in the halls of residence for 30 days. The voltages of the E-PERMs were taken using the SPER-1 Reader whilst the LR-115 was chemically etched to reveal the alpha tracks. The mean radon exposure level for LR-115 was 6.8 mSv (range: 3.1- 9.1 mSv) whiles the mean exposure for the E-PERM was 3.6 mSv (range: 1.7-5.3 mSv). The results obtained also indicated that the exposure levels measured by both the E-PERM and the LR-115 detectors were generally below the Environmental Protection Agency (US-EPA) guideline limit of 8 mSv. However, some rooms had their exposure levels (measured with the LR-115 detector) above the remedial guideline limit of 8 mSv, but far below the immediate action limit of 20 mSv. Most of a student time is spent indoors. There is therefore the need to have a fair idea the radon concentration and exposure levels in rooms since radon has been identified as a carcinogenic gas.
机译:该研究试图通过加纳LR-115 TypeII固态核径迹探测器(SSNTD)和E-PERM探测系统确定加纳海角海岸大学新址宿舍楼内某些房间的Rad暴露水平。将塑料LR-115检测器的零件用铝箔覆盖并固定在塑料支架中,以使检测器的有效部分(涂层部分)暴露(裸露),朝下,并与E-PERM一起放置在一个位置在学生宿舍的每个选定房间中停留30天。 E-PERM的电压是使用SPER-1读卡器获取的,而LR-115则经过化学蚀刻以显示出α迹线。 LR-115的平均ra暴露水平为6.8 mSv(范围:3.1- 9.1 mSv),而E-PERM的平均exposure暴露水平为3.6 mSv(范围:1.7-5.3 mSv)。获得的结果还表明,由E-PERM和LR-115检测器测得的暴露水平通常低于环境保护署(US-EPA)的8 mSv指导限值。但是,某些房间的暴露水平(用LR-115检测器测量)高于补救指导限值8 mSv,但远低于即时行动限值20 mSv。一个学生的大部分时间都花在室内。因此,由于since已被确认为致癌气体,因此需要对房间中的concentration浓度和暴露水平有一个清晰的认识。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号