Background and aims: There are many Q-switched lasers. The Q-switched ruby laser is the one most popularly used in dermatology, aesthetic surgery and plastic surgery, to remove pigmented lesions or tattoos. Correct and regular calibration of such a system is essential. However, some clinics fail to perform this with the excuse of having no measuring instrument (MI) in their offices or treatment rooms in some of their hospitals or clinics, or even the case of well-known medical universities in Japan. The present article explains the precise calibration procedure and beam pattern checking for the Q-switched ruby systems in the first author's clinic.Rationale: In the case of treatment with a medical laser, the calibration and the irradiated pattern (IP) check of the laser being used for treatment are the most important factors for treatment efficacy and safety. If these factors change, the treatment result could be different from that expected. Such kind of data are not acceptable as scientific information for a presentation or published paper. With such unreliable results and incorrect beam pattern, replicating such a study would be impossibleRegular calibration check: In our clinic, we have 2 Q-switched ruby laser systems. On a daily basis, the beam patterns, both the optical axis of the beam and its treatment footprint, are checked on dedicated printed sheets and footprint paper, respectively, at the beginning of the day and after the last procedure. Every two weeks we calibrate our systems in-house using a precise MI. Every six months we calibrate the systems in-house with the MI, and then we send the systems back to the manufacturers for calibration. Once every year, we have our MI calibrated by an accredited facility in Japan. In this way, we are not only ensuring accurate and safe treatment for our patients, but we are also producing accurate system and treatment data which can be replicated by others, the basis of evidence-based medicine.
机译:背景和目的:有很多调Q激光器。 Q开关红宝石激光器是在皮肤病学,美容外科和整形外科中最常用的一种,用于去除色素沉着的病变或纹身。正确,定期地对此类系统进行校准至关重要。但是,某些诊所无法以某些医院或诊所的办公室或治疗室中没有测量仪器(MI)为借口,甚至以日本著名的医学院为例。本文介绍了第一作者诊所中Q转换红宝石系统的精确校准程序和光束方向图检查。理论:在使用医用激光治疗的情况下,应进行校准和辐照方向图(IP)检查用于治疗的激光数量是影响治疗效果和安全性的最重要因素。如果这些因素发生变化,则治疗结果可能与预期的不同。此类数据不能作为演示文稿或已发表论文的科学信息。有了这样不可靠的结果和不正确的光束方向图,就不可能进行这样的研究定期校准检查:在我们的诊所中,我们有2个Q开关红宝石激光系统。在每天的开始和最后一次操作之后,每天都要在专用的打印纸和足迹纸上分别检查光束的光轴及其治疗足迹的光束模式。每隔两周,我们会使用精确的MI对内部系统进行校准。我们每六个月使用MI对内部系统进行一次校准,然后将系统发回给制造商进行校准。每年一次,我们会通过日本认可的工厂对MI进行校准。这样,我们不仅确保为患者提供准确和安全的治疗,而且还产生了可以被他人复制的准确的系统和治疗数据,这是循证医学的基础。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号