首页> 外文期刊>National Journal of Community Medicine >Evaluation of Cold Chain Practices in Urban Health Centers of a Metro City in India
【24h】

Evaluation of Cold Chain Practices in Urban Health Centers of a Metro City in India

机译:印度大城市城市卫生中心冷链实践评估

获取原文
       

摘要

Background: National Family Health Survey report (NFHS)-3 reports revealed that immunization coverage in India among children between 12-23 months was low at 43.5%. In lieu of strengthening Routine Immu-nization (RI), Government of Karnataka undertook state-wide training of Medical officers and Health workers on RI with concurrent efforts of strengthening cold chain system in health centers. With this background, this study was undertaken to assess the cold chain practices in urban health centers of Bangalore city. Methodology: This Cross-sectional study was conducted during Octo-ber-December 2008 in three-zones of Bruhat Bangalore Mahanagara Palike (BBMP) covering 35 units. Physical verification of the available cold chain equipments was done using predesigned pretested checklist and face to face interview of cold chain handlers was employed. Results: Of 35 centers, 33(94%) and 32(91%) of them had atleast one functional Ice-lined refrigerator(ILR) and one deep freezer(DF) respectively. Good storage code practice was practiced in 12 out of 33 ILRs. Functional thermometer was available in 31(91%) ILRs of which 23(74%) had temperature in the recommend range. With respect to knowledge of cold chain handlers on RI, 86% were trained on RI and their overall knowledge regarding cold chain practices was satisfactory except for knowledge on temperature in DF and on conditioning of ice-packs. Conclusion: Availability of cold chain equipments has improved and Cold storage practice was good/fair in most of the centers. Knowledge of cold chain handlers was low with respect to select cold chain practices.
机译:背景:《全国家庭健康调查报告》(NFHS)-3报告显示,印度12-23个月之间儿童的免疫接种率很低,仅为43.5%。作为加强常规免疫的替代品,卡纳塔克邦政府在全美范围内对医务人员和卫生工作者进行了RI培训,同时努力加强卫生中心的冷链系统。在此背景下,本研究旨在评估班加罗尔市城市卫生中心的冷链实践。方法:该横断面研究于2008年10月12日在Bruhat Bangalore Mahanagara Palike(BBMP)的三个区域中进行,覆盖35个单位。使用预先设计的预先测试清单对可用的冷链设备进行了物理验证,并进行了对冷链操作员的面对面采访。结果:在35个中心中,分别有33个(94%)和32(91%)至少具有一台功能性冰衬冰箱(ILR)和一台深冰柜(DF)。 33个ILR中有12个实施了良好的存储代码惯例。功能温度计可用于31个(91%)ILR,其中23个(74%)的温度在建议范围内。关于RI上的冷链处理人员知识,有86%的人接受了RI培训,除了关于DF中的温度和冰袋调节方面的知识外,他们关于冷链实践的整体知识令人满意。结论:在大多数中心,冷链设备的可用性得到了改善,冷藏实践良好/合理。就选择冷链实践而言,冷链处理人员的知识水平很低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号