首页> 外文期刊>Engineering >Experimental and Numerical Evaluation and Optimization of a Non Standard Pitot/Sampling Probe
【24h】

Experimental and Numerical Evaluation and Optimization of a Non Standard Pitot/Sampling Probe

机译:非标准皮托管/采样探头的实验和数值评估及优化

获取原文
           

摘要

An isokinetic sampling probe is designed and constructed to measure entrained liquid droplet fluxes in separated gasliquid pipe flows. This probe also has the capability of working as a non-standard Pitot tube when the sampling is stopped. CFD simulations using the commercial software Ansys CFX were carried out for single phase gas flow to analyze the non-standard design. Pitot tube velocity calculations and isokinetic sampling conditions were studied. The predicted results were compared against theoretical velocity profiles from the literature and with gas single phase experimental data acquired in a horizontal 49 m long steel pipeline with an internal diameter of 69 mm. The experiments were done by using a dense gas (SF6) at 7 bara. An asymmetry of the experimental velocity profiles reproduced with the numerical simulations. The CFD simulations made it possible to verify the design and predict and correct an installation problem.
机译:设计和构造了一个等速采样探头,以测量分离的气液管道流中夹带的液滴通量。停止采样后,此探头还可以用作非标准的皮托管。使用商业软件Ansys CFX对单相气流进行了CFD模拟,以分析非标准设计。研究了皮托管速度和等速采样条件。将预测结果与文献中的理论速度曲线进行了比较,并与在49 mm长的水平内径为69 mm的水平水平钢管中获得的气体单相实验数据进行了比较。通过使用7 bara的浓气体(SF6)进行实验。数值模拟再现了实验速度分布的不对称性。 CFD仿真使验证设计,预测和纠正安装问题成为可能。