首页> 外文期刊>Korean journal of radiology : >Fluid Attenuated Inversion Recovery (FLAIR) Imaging of the Normal Brain: Comparisons between Under the Conditions of 3.0 Tesla and 1.5 Tesla
【24h】

Fluid Attenuated Inversion Recovery (FLAIR) Imaging of the Normal Brain: Comparisons between Under the Conditions of 3.0 Tesla and 1.5 Tesla

机译:正常大脑的液体衰减倒置恢复(FLAIR)成像:在3.0 Tesla和1.5 Tesla条件下的比较

获取原文
获取外文期刊封面目录资料

摘要

Objective The aim of this study was to evaluate the differences in normal brain MRI findings between under 3.0 Tesla (T) and 1.5T MRI conditions with the use of the fluid attenuated inversion recovery (FLAIR) sequences. Materials and Methods Eleven normal adults underwent imaging with the use of the FLAIR sequences on both 1.5T and 3.0T scanners. Two neuroradiologists compared the signal intensity (SI) of the centrum semiovale (CS), pulvinar thalami (PT) and normal iron deposit structures (IDSs) on the 3.0T and 1.5T FLAIR images, and they evaluated three MRI findings qualitatively: high SI of CS; low SI of PT; low SI of IDS. We also evaluated signal-to-noise ratios (SNRs) for the CS, PT, red nucleus and cerebellar dentate nucleus on the FLAIR images. Results Based on qualitative analyses, the 3.0T FLAIR images showed all three MRI findings for all cases. Low SI for the PT in seven cases (64%), high SI of the CS in one case (9%) and low SI of the cerebellar dentate nucleus in one case (9%) were visualized only on 3.0T FLAIR images. The mean SNRs of the PT, red nucleus and dentate nucleus in patients where 3.0T FLAIR imaging was performed were significantly lower as compared with the SNRs on 1.5T FLAIR images. The SNR of the CS was not significantly different between under the two magnetic field strengths ( p > 0.05). Conclusion We have demonstrated that normal, high and low SIs of the CS, PT and IDS on 3.0T FLAIR images were depicted more frequently and more prominently as compared with those on 1.5T FLAIR images in normal adult brains.
机译:目的本研究的目的是使用液体衰减倒置恢复(FLAIR)序列评估在3.0 Tesla(T)和1.5T MRI条件下正常脑MRI表现的差异。材料和方法11名正常成年人在1.5T和3.0T扫描仪上使用FLAIR序列进行了成像。两名神经放射科医生在3.0T和1.5T FLAIR图像上比较了半腔卵(CS),丘脑丘脑(PT)和正常铁沉积结构(IDS)的信号强度(SI),并定性评估了三个MRI表现:高SI CS PT的SI低; IDS的SI低。我们还评估了FLAIR图像上CS,PT,红色核和小脑齿状核的信噪比(SNR)。结果基于定性分析,3.0T FLAIR图像显示了所有病例的所有三个MRI表现。仅在3.0T FLAIR图像上可以看到7例(64%)的PT的低SI,1例(9%)的CS高SI和1例(9%)的小脑齿状核低SI。与进行1.5T FLAIR成像的SNR相比,进行3.0T FLAIR成像的患者的PT,红色核和齿状核的平均SNR明显较低。在两种磁场强度下,CS的SNR均无显着差异(p> 0.05)。结论我们已经证明,与正常成人大脑中的1.5T FLAIR图像相比,在3.0T FLAIR图像上CS,PT和IDS的正常,高和低SI的描绘更为频繁和突出。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号