首页> 外文期刊>Engineering >Effects of Anthropometry Variations on Physiological Parameters of Heart Rate, Oxygen Consumption, Aerobic Power While Performing Manual Operation at Fixed Vice Height
【24h】

Effects of Anthropometry Variations on Physiological Parameters of Heart Rate, Oxygen Consumption, Aerobic Power While Performing Manual Operation at Fixed Vice Height

机译:在固定虎钳高度进行手动操作时,人体测量学变化对心率,耗氧量,有氧运动生理参数的影响

获取原文
           

摘要

This study investigated the effect of fixed height standing-workstation on different people with diverse anthropometry dimensions. Measurements of some anthropometric and physiological parameters are carried out as bases for the calculation of body mass index (BMI) and the determination of the maximum heart rate (HR_(max)) and aerobic power (VO_(2)max) of individual subject while performing manual cutting operation with hacksaw on fixed vice height of 940 mm. Twenty subjects (S1 to S20) parted 2 mm thick square-pipe of 25 mm × 25 mm. Each subject carried out cutting operation in 5 replicates and their physiological parameters during activities are measured to determine their expended energy (EE) and oxygen consumption rate (VO_(2)). The results showed that subject S4 with BMI of 20.76 kg/m~(2) has maximum cutting rate of 5.33 stroke/s, while subject S8 with BMI of 23.39 kg/m~(2) has minimum cutting rate of 0.92 stroke/s. There was a statistically significant effect on the interaction between BMI, EE and Cutting rate, with F = 827.54, P = 0.000, R~(2) = 0.967 and S = 1.749 units. Subject S11 was discovered to have VO_(2) (28.54 l/min) and VO_(2)max (24.36 ml/min/kg), with highest value of EE (2.94 kcal/min). Wear rates of 1.86 teeth/s and 9.55 teeth/s have the same energy cost (EE = 0.87 kcal/min) but different cutting time of 36.65 s (S18) and 10.89 s (S20) respectively. This could explain in-part that excess 25.76 s utilized in operation time by subject S18 is responsible for keeping approximately 7.7 teeth intact as regards tool management. EE and Tool Wear Rate in one-way analysis of variance, were statistically significant (F = 45.87, P = 0.000, R~(2) = 54.69% and S = 1.617 units) at 0.05 level.
机译:这项研究调查了固定高度站立式工作站对不同人体测量学尺寸的不同人群的影响。一些人体测量学和生理学参数的测量是计算体重指数(BMI)以及确定个体受试者的最大心率(HR_(max))和有氧能力(VO_(2)max)的基础。用钢锯在940 mm的固定虎钳高度上执行手动切割操作。二十名受试者(S1至S20)分开了25毫米×25毫米的2毫米厚方管。每个受试者进行5次重复切割操作,并测量其在活动期间的生理参数,以确定其消耗的能量(EE)和耗氧率(VO_(2))。结果显示,BMI为20.76 kg / m〜(2)的受试者S4的最大切割速率为5.33冲程/秒,而BMI为23.39 kg / m〜(2)的受试者S8的最小切割速率为0.92冲程/秒。 。 F = 827.54,P = 0.000,R〜(2)= 0.967和S = 1.749个单位,对BMI,EE和切削速率之间的相互作用具有统计学意义的影响。发现受试者S11具有VO_(2)(28.54l / min)和VO_(2)max(24.36ml / min / kg),具有最高的EE值(2.94kcal / min)。 1.86齿/秒和9.55齿/秒的磨损率具有相同的能量成本(EE = 0.87 kcal / min),但切割时间分别为36.65 s(S18)和10.89 s(S20)。这可以部分解释为,受试者S18在操作时间中使用了25.76 s以上的多余时间,可以使大约7.7颗牙齿完好无损。单因素方差分析中的EE和工具磨损率在0.05水平上具有统计学显着性(F = 45.87,P = 0.000,R〜(2)= 54.69%和S = 1.617单位)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号