Objectives . The aim of our study was to evaluate the LIAISON? system for the detection of GDH of C. difficile by comparing the results with those obtained with the our routine EIA test, from both of unselected samples and selected samples according to the Bristol scale for stool consistency. Study Design . We examined 114 unselected stool samples (Group 1) and 104 selected samples according to the Bristol scale (type 4-7: Group 2) for the detection of GDH with enzyme immunoassay (EIA) and chemiluminescence LIAISON? system. In case of positivity for one or both tests toxins A and B were searched, with EIA, and, in case of negativity of the toxins, the test of gene amplification for the search of the locus of pathogenicity for toxins A and B was performed. Results . In Group 1, sixteen samples were positive for both tests for GDH, 93 negative for both tests, and five discordant (three EIA positive and LIAISON? negative; two EIA negative and LIAISON? positive): total concordance between the two methods: 95.6%. Of the five discordant samples, all were toxin A & B negative, of these only one was positive to molecular biology. In Group 2, fifteen samples were positive for both tests for GDH, 89 negative for both tests and no discordant: total concordance between the two methods: 100%. Conclusions . Our data indicate a perfect correlation between LIAISON? and EIA, when samples are chosen according to stool consistency at least grade 4 of the Bristol scale.The possibility to use an automatic and fast system, like LIAISON?, also allows an optimization of workflows.
机译:目标。我们研究的目的是评估LIAISON?通过将结果与我们常规EIA测试获得的结果进行比较,从未选择的样品和根据布里斯托尔量表选择的布里斯托尔量表中选择的样品中比较结果,来检测艰难梭菌的GDH。学习规划 。我们根据Bristol量表(4-7型:第2组)检查了114份未选择的粪便样本(第1组)和104份选择的样本,以通过酶免疫测定(EIA)和化学发光法检测GDH。系统。在一种或两种测试均为阳性的情况下,用EIA搜索毒素A和B,而在阴性的情况下,进行基因扩增测试以寻找毒素A和B的致病性位点。结果。在第1组中,GDH的两种检测均为16份阳性,两种检测均为93份阴性,还有5种不一致(3个EIA阳性和LIAISON?阴性;两个EIA阴性和LIAISON?阳性):两种方法之间的总一致性:95.6% 。在五个不一致的样本中,所有样本均为A和B毒素阴性,其中只有一个对分子生物学呈阳性。在第2组中,GDH的两项检测均为15份阳性,两项检测均为89阴性,并且没有不一致:两种方法之间的总一致性:100%。结论。我们的数据表明LIAISON?当根据粪便稠度选择至少布里斯托尔等级4级的样本时,可以使用自动和快速系统(如LIAISON?)来优化工作流程。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号