Introduction: In addition to sterility testings for common bacteria, from 2006 on we have introduced in our laboratory sterility tests for mycobacteria on surgical instruments such as bronchoscope and lava-endoscope fluid used for their sterilization as well. Methods: Bronchology and Pneumology SUN departments, doing bronchoscopies, regularly send to our laboratory bronchoscopes washing fluids. Bronchology department also sends liquids used in lavaendoscopes. Our standard protocol consists of liquids inoculation directly on Lowenstein - Jensen (LJ) solid ground and on Middlebrook 7H9 liquid medium into Mgit test tubes, both produced by Becton Dickinson, within 42 days (1, 5, 6). Results: When growth of acid-alcohol resistant bacilli was detected, they were identified through probes or Accuprobe bioMérieux Inno- LIPA Mycobacteria by Innogenetics. All positivite results were related to M. Gordonae. As for the liquids examined, we found one positivite result in liquid medium in 2006 and none in 2007. On the contrary, in 2008 and the first 6 months of 2009, we have identified the following positive results: 2008 - 2009 (6m) LJ pos TOT 20 C. Lavaendoscope 8 V. 12 FBS We linked the positive findings on equipment with positivity for M. gordonae observed in patients undergoing bronchoscopy. Conclusions: Data analysis indicates within the period 2008-2009 we observed a recurring positivity for M. gordonae on equipment and therefore in some patients. On a careful evaluation, they showed no signs of clinical infection, also considering that this mycobacteria is usually a saprophyte (2, 3, 4). However, the protocol we adopted allowed us to recognize equipment contamination at birth and to urge fellow users to review sterilization protocols.
机译:简介:除了对常见细菌进行无菌测试之外,从2006年开始,我们还在实验室仪器上对分枝杆菌进行了无菌测试,这些测试针对手术器械(例如用于对其进行灭菌的支气管镜和熔岩内窥镜检查液)进行。方法:支气管和肺炎科SUN部门做支气管镜检查,定期将支气管镜送往我们的实验室。支气管科还发送了用于腹腔镜的液体。我们的标准协议包括在42天(1、5、6)内将液体直接接种在Lowenstein-Jensen(LJ)固体地面上以及在Middlebrook 7H9液体培养基上的Bgiton Dickinson生产的Mgit试管中。结果:当检测到耐酸酒精杆菌的生长时,通过Innogenetics通过探针或AccuprobebioMérieuxInno-LIPA分枝杆菌进行鉴定。所有积极的结果均与M. Gordonae有关。至于所检查的液体,我们在2006年的液体培养基中发现了一个阳性结果,而在2007年没有发现。相反,在2008年和2009年的前6个月中,我们发现了以下积极结果:2008-2009(6m)LJ pos TOT 20 C. Lavaendoscope 8 V. 12 FBS我们将在支气管镜检查中观察到的设备阳性结果与戈登分支杆菌的阳性联系起来。结论:数据分析表明,在2008-2009年期间,我们在设备上观察到了戈登支原体的复发阳性,因此在某些患者中也是如此。经过仔细评估,他们没有显示出临床感染的迹象,还考虑到这种分枝杆菌通常是腐生菌(2、3、4)。但是,我们采用的协议允许我们识别出出生时的设备污染,并敦促其他用户查看灭菌协议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号