Background: Due to its use of ionising radiation, the field of nuclear medicine is a unique and significant part of medical diagnostics and patient treatment. The aim of this study was to assess the internal exposure of nuclear medicine employees to radioiodine 131I and technetium 99mTc as well as to assess the external exposure doses. Material and Methods: The radioiodine 131I and technetium 99mTc contents in the thyroid of staff members (about 100 persons) dealing with these radionuclides have been measured in four departments of nuclear medicine. The measurements were conducted with a portable detection unit for in situ measurements of radioiodine and technetium. High sensitivity environmental thermoluminescent dosimeters (TLD) were used to measure the external exposure dose. Results: The average values and ranges of radioiodine 131I activity measured in the thyroids of all of the medical units' employees were: 83 Bq (range: 70-250 Bq), 280 Bq (range: 70-4000 Bq), 275 Bq (range: 70-1000 Bq) for technical staff, nuclear medicine staff and hospital services staff, respectively. The mean value of technetium 99mTc content in the thyroids of nuclear medicine staff was approximately 1500 Bq (range: 50- -1800 Bq). External exposure dose rates were in the range of 0.5-10 μGy/h. Conclusions: The calculated average effective dose for particular person caused by the inhalation of radioiodine 131I is below 5% of 20 mSv/year (occupational exposure limit). Med Pr 2013;64(5):625–630
机译:背景:由于使用电离辐射,核医学领域是医学诊断和患者治疗的独特且重要的组成部分。这项研究的目的是评估核医学员工对放射性碘131I和99mTc的内部暴露,并评估外部暴露剂量。材料和方法:在四个核医学科室中测量了处理这些放射性核素的工作人员(约100人)的甲状腺中的放射性碘131I和99mTc含量。使用便携式检测装置进行测量,以进行放射性碘和tech的原位测量。使用高灵敏度环境热发光剂量计(TLD)来测量外部暴露剂量。结果:在所有医疗单位员工的甲状腺中测得的放射性碘131I活性的平均值和范围是:83 Bq(范围:70-250 Bq),280 Bq(范围:70-4000 Bq),275 Bq(范围:70-1000 Bq)分别用于技术人员,核医学人员和医院服务人员。核医学人员甲状腺中99 99mTc含量的平均值约为1500 Bq(范围:50- -1800 Bq)。外部暴露剂量率在0.5-10μGy/ h的范围内。结论:吸入放射性碘131I引起的特定人的平均有效剂量低于20 mSv /年(职业暴露极限)的5%。 Med Pr 2013; 64(5):625-630

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号