首页> 外文期刊>Medical principles and practice: international journal of the Kuwait University, Health Science Centre >Occupational Radiation Exposure among the Staff of Departments of Nuclear Medicine and Diagnostic Radiology in Kuwait
【24h】

Occupational Radiation Exposure among the Staff of Departments of Nuclear Medicine and Diagnostic Radiology in Kuwait

机译:科威特核医学和放射诊断学部门工作人员的职业辐射暴露

获取原文
           

摘要

Objectives: To investigate radiation exposure among the staff of departments of nuclear medicine (NM) and diagnostic radiology (DR) during 2008 and 2009 and to compare the mean doses received with the limit of 20 mSv/year of the International Commission of Radiological Protection (ICRP). Materials and Methods: The whole-body dose or effective dose, i.e. Hp(10), and the skin dose, i.e. Hp(0.07), of the staff of departments of NM and DR in Kuwait for the period of 2008 and 2009 were taken from the national thermoluminescent dosimetry database. A total of 1,780 radiation workers, grouped as NM physicians, radiologists, NM technologists, and DR technologists, from 7 departments of NM and 12 departments of DR were included. The annual average Hp(10) and Hp(0.07) were calculated for each group and comparisons were made between the groups and the years. A two-sided Mann-Whitney test was carried out, at the p = 0.05 level, to compare the means. The mean Hp(10) was compared with the limits of the ICRP. Results: Of the 16 distributions of Hp(10) and Hp(0.07), 10 were normal, with a mean annual Hp (10) in 2008 of 1.06, 1.03, 1.07, and 1.05 mSv for NM physicians, radiologists, NM technologists, and DR technologists, respectively. The corresponding Hp(0.07) values for 2008 were 1.03, 1.00, 1.05, and 1.03 mSv, respectively. Small but significant (p 0.072) differences were found. Conclusion: The annual average Hp(10) was well below the limit of the ICRP. ? 2013 S. Karger AG, Basel
机译:目的:调查2008年至2009年期间核医学(NM)和放射诊断学(DR)部门工作人员的放射线照射,并比较国际放射防护委员会(International放射线保护委员会)限制的平均剂量(每年20 mSv /年)( ICRP)。材料与方法:取2008年至2009年科威特NM和DR部门工作人员的全身剂量或有效剂量Hp(10)和皮肤剂量Hp(0.07)。来自国家热发光剂量数据库。包括来自NM的7个部门和DR的12个部门的总共1,780名放射工作者,分为NM医师,放射线学家,NM技术员和DR技术员。计算每组的年平均Hp(10)和Hp(0.07),并比较各组与年份。在p = 0.05的水平上进行了双面Mann-Whitney检验,以比较平均值。将平均Hp(10)与ICRP的限制进行比较。结果:在NM医师,放射科医生,NM技术人员的16种Hp(10)和Hp(0.07)分布中,有10种是正常的,2008年的年平均Hp(10)为1.06、1.03、1.07和1.05 mSv。和DR技术专家。 2008年相应的Hp(0.07)值分别为1.03、1.00、1.05和1.03 mSv。发现差异很小但很显着(P = 0.072)。结论:年平均Hp(10)远低于ICRP的限制。 ? 2013 S.Karger AG,巴塞尔

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号