The inverted cup device for blood transfer on malaria RDTs: ease of use, acceptability and safety in routine use by health workers in Nigeria

机译:用于在疟疾RDT上进行血液转移的倒置杯装置:尼日利亚卫生工作者在日常使用中的易用性,可接受性和安全性

获取原文
       

摘要

BackgroundMalaria rapid diagnostic tests (RDTs) are becoming widely adopted for case management at community level. However, reports and anecdotal observations indicate that the blood transfer step poses a significant challenge to many users. This study sought to evaluate the inverted cup device in the hands of health workers in everyday clinical practice, in comparison with the plastic pipette, and to determine the volume accuracy of the device made of a lower-cost plastic. MethodsThe volume accuracy of inverted cup devices made of two plastics, PMMA and SBC, was compared by transferring blood 150 times onto filter paper and comparing the blood spot areas with those produced by 20 reference transfers with a calibrated micropipette. The ease of use, safety and acceptability of the inverted cup device and the pipette were evaluated by 50 health workers in Nigeria. Observations were recorded on pre-designed questionnaires, by the health workers themselves and by trained observers. Focus group discussions were also conducted. ResultsThe volume accuracy assessment showed that the device made from the low-cost material (SBC) delivered a more accurate volume (mean 5.4?μL, SD 0.48?μL, range 4.5–7.0?μL) than the PMMA device (mean 5.9?μL, SD 0.48?μL, range 4.9–7.2?μL). The observational evaluation demonstrated that the inverted cup device performed better than the pipette in all aspects, e.g. higher proportions of health workers achieved successful blood collection (96%, vs. 66%), transfer of the required blood volume (90%, vs. 58%), and blood deposit without any loss (95%, vs. 50%). Majority of health workers also considered it’ very easy’ to use (81%),’very appropriate’ for everyday use (78%), and 50% of them reported that it was their preferred BTD. ConclusionsThe good volume accuracy and high acceptability of the inverted cup device shown in this study, along with observed ease of use and safety in hands of health workers, further strengthens prior findings which demonstrated its higher accuracy as compared with other BTDs in a laboratory setting. Altogether, these studies suggest that the inverted cup device should replace other types of devices for use in day-to-day malaria diagnosis with RDTs.
机译:背景技术疟疾快速诊断测试(RDT)已被社区一级的病例管理广泛采用。然而,报告和轶事观察表明,输血步骤对许多使用者构成了重大挑战。这项研究试图与塑料移液器相比,在日常临床实践中评估卫生工作者手中的倒杯装置,并确定由低成本塑料制成的装置的体积精度。方法通过将血液150次转移到滤纸上,并用校准的微量移液器将血点面积与20次参考转移产生的血斑面积进行比较,比较由两种塑料(PMMA和SBC)制成的倒杯装置的体积精度。尼日利亚的50名卫生工作者对倒杯装置和移液器的易用性,安全性和可接受性进行了评估。卫生工作者自己和训练有素的观察员将观察结果记录在预先设计的调查表中。还进行了焦点小组讨论。结果体积准确度评估表明,与PMMA装置(平均5.9?L)相比,使用低成本材料(SBC)制成的装置可提供更准确的体积(平均5.4?L,SD 0.48?L,范围4.5–7.0?L)。 ,SD 0.48 µL,范围4.9–7.2 µL)。观察评估表明,倒置杯装置在所有方面(例如,更高比例的卫生工作者成功完成了采血(96%,对66%),所需血液量的转移(90%,对58%)和无任何损失的血液沉积(95%,对50%) 。大多数卫生工作者还认为使用非常容易(81%),非常适合日常使用(78%),其中50%的人表示这是他们的首选BTD。结论本研究显示的倒置杯装置具有良好的体积精确度和较高的可接受性,以及观察到的卫生工作者易于使用和安全的特点,进一步加强了先前的发现,与实验室其他BTD相比,其准确性更高。总而言之,这些研究表明倒置杯装置应替代其他类型的装置,用于使用RDT进行日常疟疾诊断。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号