This study describes the performance evaluation of an energy management system, based on electricity consumption, for a Gen 6 Thin Film Transistor Liquid Crystal Display (TFT-LCD) panel plant. Of the various production lines and facility systems, the array system and the compressed dry air consumed the most electricity of 21.8% and 19.8%, respectively, while the public utility used only 1.6% of the total electricity. The baseline electricity consumptions were correlated well ( R 2 ≥ 0.77) to the monthly average wet-bulb temperatures of ambient air and the panel yield rates, which were determined by the product yield over the equipment available time index. After implementing the energy saving projects, the energy conservation performance was determined using a three-parameter change-point regression model incorporated with the panel yield rates. The post-retrofit monthly savings of the total electricity consumption for the panel manufacture were 5.35%–10.36%, with the efficiency of the electricity performance revealing an upswing trend following the implementation of the energy management system.
机译:这项研究描述了基于电能消耗的第六代薄膜晶体管液晶显示器(TFT-LCD)面板工厂的能源管理系统的性能评估。在各种生产线和设施系统中,阵列系统和压缩干燥空气消耗的电能最多,分别为21.8%和19.8%,而公用事业仅消耗了总电能的1.6%。基线耗电量与周围空气的月平均湿球温度和面板的良率之间的相关性很好(R 2≥0.77),这由设备可用时间指标上的产品良率决定。实施节能项目后,使用包含面板生产率的三参数变化点回归模型确定节能表现。改造后的面板制造商每月总耗电​​量为5.35%–10.36%,随着能源管理系统的实施,电力效率表现出上升的趋势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号