首页> 外文期刊>Experimental and clinical transplantation >Venous Outflow Reconstruction Using an Expanded Polytetrafluoroethylene Vascular Graft in Living-Donor Liver Transplant: A Single-Center Experience
【24h】

Venous Outflow Reconstruction Using an Expanded Polytetrafluoroethylene Vascular Graft in Living-Donor Liver Transplant: A Single-Center Experience

机译:在活体供体肝移植中使用扩展的聚四氟乙烯血管移植物进行静脉流出重建:单中心体验。

获取原文
       

摘要

Objectives: Limited studies have focused on the feasibility and technical requirements of using expanded polytetrafluoroethylene vessel grafts for venous outflow reconstruction in a living-donor liver transplant using right liver grafts without the middle hepatic vein. Materials and Methods: Between August 2007 and December 2012, thirty-two patients who had received an expanded polytetrafluoroethylene vascular graft for outflow reconstruction during a living-donor liver transplant using a right liver graft without the middle hepatic vein were retrospectively reviewed. Preoperative and operative data, complications, and mortality were compared among patients who received the expanded polytetrafluoroethylene grafts with individual anastomoses (n = 18) or confluent anastomoses (n =14). Results: For patients who had received an individual and a confluent anastomosis, graft reconstruction time was 25.8 and 14.9 minutes ( P = .000). No cases of graft occlusion occurred during first 72 hours after surgery. Although 5 patients (15.6%) died within 90 days, none of the deaths were associated with the vascular grafts. Operative mortality was not statistically different between patients who had received an individual anastomosis (3/18, 16.7%) and those who had received a confluent anastomosis (2/14, 14.3%) ( P = 1.000). Conclusions: Individual and confluent anastomoses using an expanded polytetrafluoroethylene vascular graft is a feasible approach to venous outflow reconstruction in a living-donor liver transplant using right liver grafts without the middle hepatic vein.
机译:目的:有限的研究集中于在没有肝中静脉的右肝移植物的活体供肝移植中,使用膨胀的聚四氟乙烯血管移植物进行静脉流出重建的可行性和技术要求。材料与方法:回顾性分析2007年8月至2012年12月间接受活体供体肝移植的32例患者,该患者在使用无肝中静脉的右肝移植物进行活体供肝移植期间进行了流出重建。比较接受扩大的聚四氟乙烯移植物并单独吻合(n = 18)或融合吻合(n = 14)的患者的术前和手术数据,并发症和死亡率。结果:对于接受单个吻合和融合吻合术的患者,移植物重建时间分别为25.8和14.9分钟(P = .000)。术后最初72小时内没有发生移植物阻塞的情况。尽管5例患者(15.6%)在90天内死亡,但死亡均与血管移植无关。接受单独吻合术的患者(3 / 18,16.7%)和接受融合吻合术的患者(2 / 14,14.3%)的手术死亡率无统计学差异(P = 1.000)。结论:使用扩展的聚四氟乙烯血管移植物进行单个和汇合的吻合术是使用无肝中静脉的右肝移植物进行活体供肝移植的静脉流出重建的可行方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号