Background. The potential of pocket-sized ultrasound devices (PUDs) to improve global healthcare delivery is limited by the lack of a suitable imaging protocol and trained users. Therefore, we investigated the feasibility of performing a brief, evidence-based cardiac limited ultrasound exam (CLUE) through wireless guidance of novice users.Methods. Three trainees applied PUDs on 27 subjects while directed by an off-site cardiologist to obtain a CLUE to screen for LV systolic dysfunction (LVSD), LA enlargement (LAE), ultrasound lung comets (ULC+), and elevated CVP (eCVP). Real-time remote audiovisual guidance and interpretation by the cardiologist were performed using the iPhone 4/iPod (FaceTime, Apple, Inc.) attached to the PUD and transmitted data wirelessly. Accuracy and technical quality of transmitted images were compared to on-site, gold-standard echo thresholds.Results. Novice versus sonographer imaging yielded technically adequate views in 122/135 (90%) versus 130/135 (96%) (P<0.05). CLUE’s combined SN, SP, and ACC were 0.67, 0.96, and 0.90. Technical adequacy (%) and accuracy for each abnormality (n) were LVSD (85%, 0.93,n=5), LAE (89%, 0.74,n=16), ULC+ (100%, 0.94,n=5), and eCVP (78%, 0.91,n=1).Conclusion. A novice can perform the CLUE using PUD when wirelessly guided by an expert. This method could facilitate PUD use for off-site bedside medical decision making and triaging of patients.
机译:背景。缺乏合适的成像协议和训练有素的用户限制了袖珍型超声设备(PUD)改善全球医疗保健服务的潜力。因此,我们研究了通过新手用户的无线指导进行简短的,循证的心脏有限超声检查(CLUE)的可行性。 3名受训人员在异地心脏科医生的指导下对27名受试者进行了PUD,以获取CLUE筛查LV收缩功能障碍(LVSD),LA增大(LAE),超声肺彗星(ULC +)和CVP升高(eCVP)。心脏病专家使用连接到PUD的iPhone 4 / iPod(FaceTime,Apple,Inc。)进行了实时的远程视听指导和解释,并以无线方式传输数据。将传输图像的准确性和技术质量与现场金标准回声阈值进行比较。新手与超声检查者的成像技术在122/135(90%)与130/135(96%)的技术上可获得足够的视野(P <0.05)。 CLUE的SN,SP和ACC总计为0.67、0.96和0.90。每个异常的技术充分性(%)和准确性(n)为LVSD(85%,0.93,n = 5),LAE(89​​%,0.74,n = 16),ULC +(100%,0.94,n = 5),和eCVP(78%,0.91,n = 1)。结论。在专家无线指导下,新手可以使用PUD执行CLUE。这种方法可以促进PUD用于异地床边医疗决策和患者分类。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号