首页> 外文期刊>Engineering and Applied Science Research >The time derivative of flux-linkage dependence on flux-linkage with partitioned-stator doubly-salient permanent-magnet generator structure
【24h】

The time derivative of flux-linkage dependence on flux-linkage with partitioned-stator doubly-salient permanent-magnet generator structure

机译:划分定子双凸极永磁发电机结构的磁链依赖于磁链的时间导数

获取原文
           

摘要

The time derivative of flux-linkage, dΨ/dt dependence on flux-linkage of partitioned-stator doubly-salient permanent-magnet generator (PS-DSPG) structure with varying the number of poles is proposed. The analysis is based on finite element method using COMSOL software. The result shows that the flux-linkage is reduced with an increasing of the number of poles. Nevertheless, the dΨ/dt is enhanced when the number of poles is increased. This is because the dΨ/dt and the flux-linkage do not only depend on the number of poles but it also depends on the flux-linkage circulation.
机译:提出了磁极链的时间导数,dΨ/ dt依赖于极数变化的分隔定子双凸极永磁发电机(PS-DSPG)结构的磁链的时间导数。该分析基于使用COMSOL软件的有限元方法。结果表明,磁通量随着极数的增加而减少。然而,当极数增加时,dΨ/ dt会增加。这是因为dΨ/ dt和磁链不仅仅取决于极数,还取决于磁链的循环。