首页> 外文期刊>Endocrine journal >The ratio of glycated albumin to hemoglobin A1c measured in IFCC units accurately represents the glycation gap
【24h】

The ratio of glycated albumin to hemoglobin A1c measured in IFCC units accurately represents the glycation gap

机译:以IFCC单位测量的糖化白蛋白与血红蛋白A1c的比值准确表示糖化间隙

获取原文
       

摘要

References(43) Cited-By(2) The glycation gap (G-gap: difference between measured hemoglobin A1c [A1C] and the value predicted by its regression on the fructosamine level) is stable and associated with diabetic complications. Measuring A1C level in International Federation of Clinical Chemistry (IFCC) units (A1C-SI; mmol/mol) and National Glycohemoglobin Standardization Program units (A1C-NGSP; %) and using glycated albumin (GA) level instead of fructosamine level for calculating the G-gap, we investigated whether the G-gap is better represented by GA/A1C ratio if expressed in SI units (GA/A1C-SI ratio) rather than in NGSP units (GA/A1C-% ratio). We examined 749 Japanese children with type 1 diabetes using simultaneous GA and A1C measurements. Of these, 369 patients were examined more than five times to assess the consistency of the G-gap and the GA/A1C ratio within individuals. The relationship of GA/A1C-% ratio to the corresponding A1C-NGSP was stronger than that of GA/A1C-SI ratio to A1C-IFCC. At enrollment, the inverse relationship between the GA/A1C-SI ratio and G-gap was highly significant (R2 = 0.95) compared with that between the GA/A1C-% ratio and G-gap (R2 = 0.69). A highly significant inverse relationship was also observed between the mean GA/A1C-SI ratio and the mean G-gaps obtained individually over time (R2 = 0.95) compared with that using the corresponding A1C-NGSP (R2 = 0.67). We conclude that the G-gap is better represented by the GA/A1C-SI ratio. We propose the use of mean GA/A1C-SI ratios easily obtained individually over time as reference values in Japanese children with type 1 diabetes (6.75 ± 0.60 [means ± SD]).
机译:参考文献(43)被引用者(2)糖化间隙(G间隙:测得的血红蛋白A1c [A1C]与果糖胺水平的回归预测值之间的差异)稳定且与糖尿病并发症相关。以国际临床化学联合会(IFCC)单位(A1C-SI; mmol / mol)和国家糖化血红蛋白标准化计划单位(A1C-NGSP;%)测量A1C水平,并使用糖化白蛋白(GA)代替果糖胺水平来计算对于G间隙,我们调查了如果以SI单位(GA / A1C-SI比率)而不是NGSP单位(GA / A1C%比率)表示,则GA间隙是否可以用GA / A1C比更好地表示。我们通过同时进行GA和A1C测量检查了749名日本1型糖尿病儿童。其中,对369名患者进行了五次以上检查,以评估个体之间G间隙和GA / A1C比的一致性。 GA / A1C-%比率与相应的A1C-NGSP的关系比GA / A1C-SI比率与A1C-IFCC的关系更强。入学时,GA / A1C-SI比与G-gap之间的反比非常显着(R2 = 0.95),而GA / A1C-%比与G-gap之间的反比(R2 = 0.69)。与使用相应的A1C-NGSP(R2 = 0.67)相比,平均GA / A1C-SI比值和随时间推移单独获得的平均G间隙之间也存在高度显着的反比关系(R2 = 0.95)。我们得出的结论是,GA / A1C-SI比可以更好地表示G间隙。我们建议使用随时间容易获得的平均GA / A1C-SI比值作为日本1型糖尿病儿童的参考值(6.75±0.60 [平均值±SD])。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号