Accuracy of densitometry of two cone beam computed tomography equipment in comparison with computed tomography

机译:与计算机断层扫描相比,两种锥形束计算机断层摄影设备的光密度测定精度

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Background The use of oral implants has been growing, and cone beam computerized tomography (CBCT) has become the method of choice for oral and maxillofacial radiology. Objective To assess the accuracy of bone densitometry in two different CBCT devices in comparison with MDCT (multi-detector CT). Methods Different concentrations of urografin, including 2.5%, 5%, 7.5%, 10%, 12.5%, were prepared, and the Hounsfield unit of these solution was measured by two CBCT devices (SORDEX CRANEX 3D and NEWTOM 5G) and one spiral CT device (SOMATOM SENSATION). Difference of output Hounsfield units in each concentration was compared in three devices. Correlation of devices with increase of urografin dose also was evaluated. Statistical analyses of the data were performed using SPSS18 and Kruskal–Wallis and Mann–Whitney U tests, along with Spearman’s correlation coefficient. Results The range of gray density for NEWTOM 5G CBCT, SORDEX 3D CBCT, and SOMATOM CT imaging systems was from 781 to 2311, 427 to 1464, and 222 to 994, respectively. There was significant difference between devices in the Hounsfield unit in all urografin concentrations (p<0.001). Also there was a significant correlation between three devices with increasing the urografin dose (p 0.95) Conclusion Our findings indicated a high correlation and linear relationship between different studied imaging systems. Although utilizing CBCT in the assessment of bone density is useful according to its lower emitted dose and less cost, clinicians should be aware of the issue that the voxel value in CBCT is not as perfect as CT.
机译:背景技术口腔植入物的使用正在增长,并且锥形束计算机断层扫描(CBCT)已成为口腔和颌面放射学的首选方法。目的评估与MDCT(多探测器CT)相比,两种不同的CBCT设备中骨密度测定的准确性。方法制备不同浓度的尿移植素,包括2.5%,5%,7.5%,10%,12.5%,并用两台CBCT设备(SORDEX CRANEX 3D和NEWTOM 5G)和一台螺旋CT测量这些溶液的Hounsfield单位设备(SOMATOM SENSATION)。在三个设备中比较了每种浓度下输出的Hounsfield单位的差异。还评估了装置与尿移植素剂量增加的相关性。使用SPSS18以及Kruskal-Wallis和Mann-Whitney U检验以及Spearman的相关系数对数据进行统计分析。结果NEWTOM 5G CBCT,SORDEX 3D CBCT和SOMATOM CT成像系统的灰度密度范围分别为781至2311、427至1464和222至994。在所有尿移植素浓度下,Hounsfield单位的装置之间存在显着差异(p <0.001)。随着尿移植素剂量的增加,三种装置之间也存在显着相关性(p 0.95)结论我们的发现表明不同研究成像系统之间存在高度相关性和线性关系。尽管根据CBCT的较低放射剂量和较低的成本,可以在骨密度评估中使用CBCT,但临床医生应意识到CBCT中体素值不如CT完美的问题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号